16
Runback ON, Setback ON,
Max Temp ON
Temperature
Runback
Set point
Heating End
Time
Temp Range available to User
Temp. increased
By user to Max.
Max Temp.
Set point
Heating Start
Setback Limit
Temperature
21
.5°C
Wed. 11:00
Set point:
COMFORT
21
.5°C
Wed. 11:00
Set point:
COMFORT
21
.5°C
Wed. 11:00
Set point:
COMFORT
When all 3 settings are activated then the user
has a choice between Setback as a minimum and
the Max temp setting as a maximum.
The Convector will always come on at the
Runback set point.
In the example above the user has activated
Runback and then increased the temperature to
the Max Temp set point after a time.
ERROR CODES
The Merida Convector continuously checks to
ensure that it is working correctly all the time,
however in some cases the convector may display
an Error code on the screen.
Below you will find each code and a short
description on the cause of each issue.
E1 Short circuit for Element controller.
E2 Very High Load >2800w.
E4 High Temperature in Controls detected.
OC Disconnected or Open circuit temperature
sensor.
SC Damaged or Short circuit temperature
sensor.
When the display shows E2 or E4 the element
will be turned off.
If the screen shows E1 the high level cutout will
open and turn the element off.
In the case of any error code shown please
contact
for support; please
include an image of your serial number and the
Error code with the email.
TROUBLESHOOTING
If the power of the Lithium
battery drops, in every
active screen a small icon
will remind the user that the
battery is flat. The time and
date is not retained if the
convector main switch is
disconnected.
If the convector is paired with an internet
connected Gateway the time and date are always
updated when the convector reconnects to the
Gateway.
When a convector has
been paired with a Gateway,
the text “Link” and an
antenna with flashing waves
appears on the top right of
the screen.
When the Gateway is not
powered or it is too far away
from convector, the Link text
alternates with a red antenna
without waves to alert the
user that the convector
cannot communicate with
the Gateway.
If a convector is paired with a Gateway, and the
internet connection is lost the heating system is
not accessible from the app.
However the running schedule remains in the
convector memory and continues with the last
user setting once the lithium battery is not flat.
The Lithium battery (CR2032) life is around 5
years from date of manufacture, this life can be
decreased depending storage conditions.
To change the battery contact your installer or
an electrician.