ATC MER1000 Operating And Installation Instructions Download Page 13

13

OFF

ON

Open Window

OK

Wed. 11:00h

21

.5°C

Set point:

OFF

ON

Self Adaptive

OK

OFF

ON

EASY mode

OK

OFF (100%)

75%

50%

20%

LowSurfaceTemp

OK

Wed. 11:00h

21

.5°C

Set point:

COMFORT

EASY

Wed. 11:00h

21

.5°C

Set point:

set temp

Status      ON

Change

Password

OK

Runback Config

Setback

Max. Temp.

OK

Runback

Confirm

OK  CANCEL

RESET

LST 23%

Wed. 11:00h

21

.5°C

Set point:

The  Open  window  setting 

will  turn  the  heating  of  the 

convector off if the unit 

detects a rapid drop in 

temperature  over  a  short 

period of time. 

To  re-activate  the  heating 

if the open window function 

has activated press any 

button the convector. 

If  the  temperature  rises 

above the minimum detected 

temperature then the heater 

will  reactivate  and  turn  the 

open  window  function  off  (i.e.  the  window  was 

closed).

If  this  function  comes  on  frequently  e.g.  in  an 

area  where  there  is  an  external  doorway,  it  is 

recommended to turn the open window function 

off. 

The Self Adaptive setting 

will  allow  the  convector  to 

calculate  the  optimum  time 

to start the heating cycle 

when running in Program 

mode.

 

If this setting is turned 

on  it  will  be  shown  in  the 

Notification  area  and  the 

heating will come on before  

the  programmed  starting 

time  so  that  the  room  is  at 

the  correct  temperature 

at 

the  programmed  starting 

time.

The 

Low 

Surface 

Temperature  (LST)  menu 

will  allow  the  output  of  the 

heater to be limited to a lower 

setting to prevent the surface 

of  the  heater  becoming  too 

hot. If a surface temperature 

of less than 43°C is required 

use the lowest setting.

It  is  recommended  that  if 

the LST function is activated 

then the convector should be 

locked  with  a  non-standard 

password after activation to 

prevent the function being 

turned off.

(See Password Section for details on changing 

the factory default password) 

EASY  Mode  is  a  simple 

mode  of  operation  where 

by only the + and – buttons 

on the convector operate to 

increase or decrease the 

temperature. The OK button 

is  de-activated.  To  turn  the 

convector on or off use the 

Main  power  button  on  the 

side of the heater. 

When running in Easy 

mode  the  screen  will  show 

EASY in the notification area 

to let the user know that the 

mode is active. 

To exit EASY mode press 

and hold the CONFIG button 

for 10 seconds, then select 

“off”.

Runback:  See  Runback 

Section on page 14

Password:  See  Password 

Section on page 14

Resetting the convector 

will return all settings to the 

factory defaults and will also 

delete  any  ‘pairing’  with  a 

Gateway.

To activate the RESET 

feature select with arrow buttons OK, and press 

the OK button.

 The first press of any button will wake up the convector any 

further button presses will activate the function required. 

Summary of Contents for MER1000

Page 1: ...R500 MER750 MER1000 MER1500 MER2000 NOTE A qualified electrician must carry out the electrical installation of this convector The Electrical installation must comply with the current UK and Irish regu...

Page 2: ...IONS 8 Manual Programming 9 Set program temperatures 9 Setting the time and date 9 Entering a program 10 Boost 11 Display settings 11 Programming with App 12 Keypad Locking Anti Tamper 12 Advanced set...

Page 3: ...r to the user ATTENTION The heaters must not be covered by clothing containers or any other objects that may block the air ventilation VERY IMPORTANT The OFF indicator shown on the heater s control pa...

Page 4: ...eater directly on the floor Make sure that the wall where the heater is going to be mounted is suitable to bear the heater s weight Use the correct fixing for the type of wall the heater is to be moun...

Page 5: ...re the maximum rate of heat convection the air circulation channels provide a very efficient convection effect The aluminium heating element ensures maximum heat output Designed and fabricated in acco...

Page 6: ...0mA We recommend that the connection box is positioned 10cm to the right of the heater and 15cm above the floor LOCATION The ideal place to site the heater is as close as possible to coolest wall in t...

Page 7: ...be used in Manual mode or Easy mode which bypasses any programming and provides simple On Off operation 2 Attach the mounting bracket to the wall using the screws provided screw through the lower hori...

Page 8: ...reen will turn blank and the convector will lose any connection with the Gateway Stand by function From any On screen press the OK Mode button until the symbol is present as shown in the following scr...

Page 9: ...g symbol will be shown indicating that the convector is producing heat When the room temperature equals or is above the set temperature the heating symbol will not be present indicating the convector...

Page 10: ...egin to flash Change the On time to the starting time the convector should heat 7 00 in our example press OK and the OFF time starts to flash Change the OFF time to the end of the heating period requi...

Page 11: ...turn off The Merida convector features a responsible consumption Eco Display mode this mode will show a coloured bar across the bottom of the screen to encourage the user to set an economical tempera...

Page 12: ...ed to lock the keypad 0 0 0 0 by default See Password Settings Chapter for further details on changing passwords To Lock the convector Press and hold the and buttons until the lock screen appears Ente...

Page 13: ...temperature at the programmed starting time The Low Surface Temperature LST menu will allow the output of the heater to be limited to a lower setting to prevent the surface of the heater becoming too...

Page 14: ...k mode for use when the heater will be installed in areas where restricted user control is required When Runback Mode is active it allows the user to set the convector to run for a specific pre set am...

Page 15: ...d is set in the Runback Temp menu Use to Set the temperature and Press OK Please note that the Runback temperature cannot be set higher than the Comfort setting in the main menu SETBACK The setback mo...

Page 16: ...e high level cutout will open and turn the element off In the case of any error code shown please contact Technical ATC ie for support please include an image of your serial number and the Error code...

Page 17: ...t mode temperature 21 C Boost mode time 1 hour Low Surface Temperature Disabled Password status Activated Password 0000 Units C Keyboard Unlocked Easy mode Disabled Runback mode Disabled Setback Disab...

Page 18: ...0005 kW 0 0005 kW 0 0005 kW 0 0005 kW In standby mode elSB 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW Type of heat output room temperature control Electronic room temperature control plus week...

Page 19: ...19 THIS PAGE IS PROVIDED FOR YOU TO MAKE NOTES FOR YOUR PROGRAMMING...

Page 20: ...is covered under the guarantee Transportation charges are not covered under the guarantee The guarantee is valid in the UK and Ireland only This guarantee is additional to your statutory rights In th...

Reviews: