ATC MER1000 Operating And Installation Instructions Download Page 10

10

22:00

OK

TIME SETTINGS
TIME

TIME
DATE
DST

TIME SETTINGS

OK

Day

Month

Year

01

01

2019

OK

TIME SETTINGS
DATE

DST
OFF

ON

OK

TIME SETTINGS

Tuesday

COPY

00:00      23:59                   

add period

ON    OFF  

mode     

  

PROGRAM

OK

Tuesday

COPY

00:00      23:59                   x

add period

ON    OFF  

mode     

  

PROGRAM

OK

Tuesday

COPY

00:00      23:59                 ok  x  

add period

ON    OFF  

mode     

  

PROGRAM

OK

Wednesday

COPY

07:00      12:00                   x
13:00      14:00                   x
17:00      20:00                   x

add period

ON    OFF  

mode     

  

PROGRAM

OK

Copy Wednesday to:

Mon           Tue

Wed

           Thu

Fri              Sat

Sun
OK       CANCEL

OK

PROGRAM

OK

CONFIG

COMFORT
ECO
ANTI-FROST

PROGRAM

SETTINGS

COMFORT

Wednesday

add period

COPY

ON    OFF  

mode   

  

OK

PROGRAM

Select TIME and press OK.

The current set time is shown on the display, to 

change time move the underline to the Hours and 

press OK.

The hours will flash, use the +/- keys to adjust 

to the correct value and press OK, move to the 

minutes and repeat to set the correct time. Once 

complete press the CONFIG button to exit.

To set the Date select the Date menu, press OK 

and enter the Day, Month and Year.

To  exit  the  Date  menu,  press  the  CONFIG 

button.

The Convector can automatically adjust the time 

offset for Daylight savings. To set this option on or 

off choose ON or OFF in the DST menu.

ENTERING A PROGRAM

Once the correct day 

is selected, select add 

period  and  press  OK.    The 

underline  will  change  to  a 

box  around  the  times  that 

can  be  changed.  Press  OK 

and the ON time will begin to 

flash. 

Change the On time to the 

starting  time  the  convector 

should heat (7:00 in our 

example),  press  OK  and 

the OFF time starts to flash. 

Change the OFF time to the 

end of the heating period 

required (e.g:12:00). 

Once  the  Times  have 

been Entered, chose the 

temperature 

set 

point 

required for the heating 

period; either Comfort 

 or 

Economy   (Set above). 

Any  time  periods  outside 

of  Comfort  or  Economy  are 

automatically  set  to  Anti-

Frost 

 . 

Once the set point is chosen choose either “OK” 

to save the setting or “x” to delete.

Extra heating times can be added by selecting 

“add period” and repeating the above procedure.

Once  the  program  for  the 

day  is  complete,  it  can  be 

copied to other days in the 

week  by  selecting  COPY 

from 

the 

programming 

screen.

The  copy  screen  will 

appear and the day that is 

being  copied  from  will  not 

be available. (Wednesday in 

the example.)

Select the days to copy to and then move the 

underline to “OK” on the screen and press the OK 

button. 

The  screen  will  change  back  to  the  program 

menu.

To Exit press CONFIG or leave the convector 

and the display will revert to the current running 

mode.

The AUTO mode of the Merida convector allows 

you to run a program designed to accommodate 

your  lifestyle.  To  enter  a  new  program  into  the 

Heater press and hold the CONFIG button until the 

CONFIG menu appears, then use the +/- buttons 

to select PROGRAM and press OK.

To enter a program into the convector first select 

the day of the week in the upper left corner of the 

programming  screen  and  press  OK,  change  the 

day to the day you want to program and press OK. 

Summary of Contents for MER1000

Page 1: ...R500 MER750 MER1000 MER1500 MER2000 NOTE A qualified electrician must carry out the electrical installation of this convector The Electrical installation must comply with the current UK and Irish regu...

Page 2: ...IONS 8 Manual Programming 9 Set program temperatures 9 Setting the time and date 9 Entering a program 10 Boost 11 Display settings 11 Programming with App 12 Keypad Locking Anti Tamper 12 Advanced set...

Page 3: ...r to the user ATTENTION The heaters must not be covered by clothing containers or any other objects that may block the air ventilation VERY IMPORTANT The OFF indicator shown on the heater s control pa...

Page 4: ...eater directly on the floor Make sure that the wall where the heater is going to be mounted is suitable to bear the heater s weight Use the correct fixing for the type of wall the heater is to be moun...

Page 5: ...re the maximum rate of heat convection the air circulation channels provide a very efficient convection effect The aluminium heating element ensures maximum heat output Designed and fabricated in acco...

Page 6: ...0mA We recommend that the connection box is positioned 10cm to the right of the heater and 15cm above the floor LOCATION The ideal place to site the heater is as close as possible to coolest wall in t...

Page 7: ...be used in Manual mode or Easy mode which bypasses any programming and provides simple On Off operation 2 Attach the mounting bracket to the wall using the screws provided screw through the lower hori...

Page 8: ...reen will turn blank and the convector will lose any connection with the Gateway Stand by function From any On screen press the OK Mode button until the symbol is present as shown in the following scr...

Page 9: ...g symbol will be shown indicating that the convector is producing heat When the room temperature equals or is above the set temperature the heating symbol will not be present indicating the convector...

Page 10: ...egin to flash Change the On time to the starting time the convector should heat 7 00 in our example press OK and the OFF time starts to flash Change the OFF time to the end of the heating period requi...

Page 11: ...turn off The Merida convector features a responsible consumption Eco Display mode this mode will show a coloured bar across the bottom of the screen to encourage the user to set an economical tempera...

Page 12: ...ed to lock the keypad 0 0 0 0 by default See Password Settings Chapter for further details on changing passwords To Lock the convector Press and hold the and buttons until the lock screen appears Ente...

Page 13: ...temperature at the programmed starting time The Low Surface Temperature LST menu will allow the output of the heater to be limited to a lower setting to prevent the surface of the heater becoming too...

Page 14: ...k mode for use when the heater will be installed in areas where restricted user control is required When Runback Mode is active it allows the user to set the convector to run for a specific pre set am...

Page 15: ...d is set in the Runback Temp menu Use to Set the temperature and Press OK Please note that the Runback temperature cannot be set higher than the Comfort setting in the main menu SETBACK The setback mo...

Page 16: ...e high level cutout will open and turn the element off In the case of any error code shown please contact Technical ATC ie for support please include an image of your serial number and the Error code...

Page 17: ...t mode temperature 21 C Boost mode time 1 hour Low Surface Temperature Disabled Password status Activated Password 0000 Units C Keyboard Unlocked Easy mode Disabled Runback mode Disabled Setback Disab...

Page 18: ...0005 kW 0 0005 kW 0 0005 kW 0 0005 kW In standby mode elSB 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW Type of heat output room temperature control Electronic room temperature control plus week...

Page 19: ...19 THIS PAGE IS PROVIDED FOR YOU TO MAKE NOTES FOR YOUR PROGRAMMING...

Page 20: ...is covered under the guarantee Transportation charges are not covered under the guarantee The guarantee is valid in the UK and Ireland only This guarantee is additional to your statutory rights In th...

Reviews: