113
INSTALLATION INSTRUCTIONS
G25/25 mbar G20/20 mbar G25/20 mbar G30/29 mbar G31/29 mbar G31/37 mbar G30/50 mbar G31/50 mbar
burner type
(kW)
(kW)
(kW)
(kW / g/h)
(kW / g/h)
(kW / g/h)
(kW / g/h)
(kW / g/h)
simmer
1.00
1.00
0.90
0.90 / 65
0.79 / 57
0.90 / 65
1.00 / 72
0.88 / 63
normal
2.00
2.00
1.80
1.60 / 115
1.41 / 101
1.60 / 115
2.00 / 144
1.76 / 127
strong
3.00
3.00
2.70
2.30 / 166
2.02 / 146
2.30 / 166
2.70 / 194
2.38 / 171
wok
4.50
4.50
4.50
3.50 / 252
3.08 / 222
3.50 / 252
4.00 / 288
3.52 / 253
wok HG96/97..M
5.70
5.70
5.00
5.00 / 396
4.85 / 350
5.50 / 396
5.50 / 396
4.75 / 342
setting up the appliance for other gas types (except HG96/HG97..M)
This appliance has been set up for natural gas. The appliance can be set
up for other gas types and pressures by means of a conversion kit. You
can order the kit from the sales and service organisation. The conversion
instructions are supplied with the kit.
gas information