iC & iC Economiser combination
boilers technical data
iC ECONOMISER COMBINATION BOILERS
iC Economiser 27
iC Economiser 35
iC Economiser 39
Part number
BE200127
BE200135
BE200139
ErP Seasonal space heating energy efficiency class
A
A
A
ErP Seasonal space heating energy efficiency (%)
94
94
94
ErP Water heating energy efficiency class
A
A
A
ErP Water heating energy efficiency (%)
94
96
96
ErP Declared load profile DHW
XXL
XXL
XXL
DHW input (kW)
29.8
40.3
42.5
CH output (kW)
23.2
31.2
31.2
Hot water flow rate @ 35°C rise (l/min)
12.6
16.1
17.0
SEDBUK 2009 (%)
89.7
89.7
89.7
Dimensions (H x W x D) (mm)
700 x 440 x 355
700 x 440 x 355
700 x 440 x 355
Boiler lift weight with jig (Kg)
43
46
46
Standard warranty (years)
10
10
10
LPG conversion kit available
Yes
Yes
Yes
NOx class
6
6
6
Ingress protection (IP)
IPX4D
IPX4D
IPX4D
Maximum equivalent horizontal flue length (m) 60/100mm
18
6
6
Maximum equivalent vertical flue length (m) 60/100mm
18
6
6
Maximum equivalent horizontal flue length (m) 80/125mm
50
45
45
Maximum equivalent vertical flue length (m) 80/125mm
50
45
45
iC COMBINATION BOILERS
iC24
iC28
iC36
iC40
Part number
BC100124
BC100128
BC100136
BC100140
ErP Seasonal space heating energy efficiency class
A
A
A
A
ErP Seasonal space heating energy efficiency (%)
94
94
94
94
ErP Water heating energy efficiency class
A
A
A
A
ErP Water heating energy efficiency (%)
85
84
90
90
ErP Declared load profile DHW
XL
XL
XL
XL
DHW input (kW)
26.6
30.3
39.3
42.0
CH output (kW)
23.2
23.2
31.2
31.2
Hot water flow rate @ 35°C rise (l/min)
10.1
11.5
14.9
16.2
SEDBUK 2009 (%)
89.7
89.7
89.7
89.7
Dimensions (H x W x D) (mm)
700 x 440 x 355
700 x 440 x 355
700 x 440 x 355
700 x 440 x 355
Boiler lift weight with jig (Kg)
41
41
44
44
Standard warranty (years)
10
10
10
10
LPG conversion kit available
Yes
Yes
Yes
Yes
NOx class
6
6
6
6
Ingress protection (IP)
IPX4D
IPX4D
IPX4D
IPX4D
Maximum equivalent horizontal flue length (m) 60/100mm
18
18
6
6
Maximum equivalent vertical flue length (m) 60/100mm
18
18
6
6
Maximum equivalent horizontal flue length (m) 80/125mm
50
50
45
45
Maximum equivalent vertical flue length (m) 80/125mm
50
50
45
45
5
Summary of Contents for BC100124
Page 1: ...Appliance Technical Guide SERVICE ENGINEER EDITION ...
Page 24: ...PCB electrical diagram LMU 24 ...
Page 35: ...Notes 35 ...