Recover IP address using default IP address
4.4.2.
The following procedure explains how to reboot the Asycube on the default IP address,
subnet mask and tcp port number to be able to modify IP address, subnet mask and tcp port
number when they are unknown and cannot be founded. Following this procedure, you are
able to connect on the Asycube with default parameters and then modify unknown
parameters.
Step 1
Unscrew the 3 screws on
both sides
(A)
and remove
the cover
Use an torx key size 10
Step 2
Place selector 1 in "off"
position
(B)
Step 3
Disconnect and reconnect the power cable (or switch off and switch on the
power on the Asycube).
The AsyCube will take default parameters at startup :
IP: 192.168.127.254
SubnetMask: 255.255.255.0
TCP Port: 4001
(A)
1
2
3
4
(B)