Installation
7
3 Installation
Overview
This section includes DV-7000/DV-8000 installation instructions for the Century, Millennium M-2000, Axiom,
Spectrum, and DispenseMate Series Dispensing Systems.
"
NOTE
For more information, refer to the manual for your particular dispensing system.
This section covers the following topics:
•
Installing the Pump
•
Software Configuration
•
Installation Verification Test
Installing the Pump
If your DV-7000/DV-8000 pump was factory installed, you do not need to perform this procedure. Proceed
with “
Installing/Changing a Fluid Syringe
” in the
Operation
section.
"
NOTE
The installation instructions below do not include installation of an upgrade kit. If the pump is
installed on a system that requires an upgrade kit, contact Asymtek Technical Support for
additional information.
WARNING!
CAUTION!
Before installing the pump, the dispensing system must be completely powered
down. Lock out and tag out power to the dispensing system to prevent accidental
restoration of power during pump installation. Refer to the manual for your particular
dispensing system for instructions.
WARNING!
The procedures in this section should be performed by trained personnel only.
Tools and Materials Needed
•
2 mm Hex Key
•
Phillips
Head
Screwdriver
•
3 mm Hex Key
•
Valve
bracket
•
4 mm Hex Key
•
Height Sensor and Bracket (application dependent)
"
NOTE
Prior to installation, use the software or dispensing system position controls to move the
dispensing head to the front center of the dispensing area. Perform a service shutdown as
specified in the applicable dispensing system manual. Remove any valve currently installed
on the dispensing head. If the valve bracket installed is incompatible with the DV-7000/DV-
8000, remove it and the Height Sensor (if present). Refer to the installation/removal
procedures in the applicable valve manual if necessary.