29
E
Initialization/Functional Restriction Setting (FUNCTION) menu
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
ALL RESET
RSET
W
0
-
ADJUSTMENT LOCK
ALCK
WR
0-2
0-2 0: OFF, 1:ON 1, 2:ON 2
º
OSD DISPLAY
LOSD
WR
0-2
0-2 0: ON 1, 1: OFF, 2: ON 2
º
LED
OFLD
WR
0-1
0-1 0: ON, 1: OFF
º
TEMPERATURE ALERT
TALT
WR
0-2
0-2 0: OFF, 1: OSD & LED, 2: LED
º
STATUS ALERT
SALT
WR
0-2
0-2 0: OFF, 1: OSD & LED, 2: LED
º
Others
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
VOLUME
VOLM
WR
0-31
0-31
º
BRIGHT
VLMP
WR
0-31
0-31
º
TEMPERATURE SENSOR
DSTA
R
0 Internal temperature normal
•
1 Internal temperature abnormal has occurred and the monitor is in standby
mode
2 Internal temperature abnormal occurred (To delete the information of
temperature abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is
dimmed
4 Temperature sensor abnormal
TEMPERATURE ACQUISITION
ERRT
R
Value Returns the temperature of the temperature sensor.
Indicates a temperature sensor abnormality when “126” is returned.
º
CAUSE OF LAST STANDBY MODE
STCA
W
0
Initialization
•
R
0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power off by the main power switch
3 Standby mode by RS-232C
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
20 Standby mode by OFF IF NO OPERATION setting
Controlling the Monitor with a PC (RS-232C)
Summary of Contents for PQ321Q
Page 1: ...LCD Monitor User Manual PQ321 Series ...
Page 37: ...37 E ...
Page 38: ...www asus com ...