32
IV. Hardware Setup
II. Components
AR1000 RAID Subsystem Hardware Reference Guide
Output Voltage Regulation, Ripple, and Noise
Output Current Capacity
Input Voltage
Safety
The power system meets all applicable clauses for UL 1950 2nd edition with-
out D3 deviations. The power system passes all tests for CUL and TUV
safety.
EMI
The power system, operating with resistive load, meets FCC class B and
CISPR 22 class B conducted limits.
Output Voltage Limits (Vdc)
Ripple/Noise
Output
Min
Nom
Max
Maximum
1
4.75V
5.00V
5.25V
50mV
p-p
2
11.40V
12.00V
12.60V
120mV
p-p
3
-4.50V
-5.00V
-5.50V
120mV
p-p
4
-10.92V -12.00V
-13.20V
120mV
p-p
2-16. Power Supply Information
Power Supply Info
Output Nom (Vdc) Max (A) Min (A)
1
5.0V
40.0
3.0
2
12.0V
12.0
1.5
3
-5.0V
0.5
0.0
4
-12.0V
0.5
0.0
Range
Min (V) Nom (V)
Max (V)
Range 1
90
115
132
Range 2
180
230
264