Temperature
Range
Resolution
Accuracy
-40~1370°C
1°C
-40°C~150°C: ± (2.5% + 4)
150°C~1370°C: ± (2.5% + 4)
-40~2000°F
1°F
-40°F~302°F: ± (2.5% + 4)
302°F~2000°F: ± (2.5% + 4)
NOTE: Different temperature sensors are configured in different temperature test ranges and
normal temperature sensors are provided for standard configuration.
DC Current
Range
Resolution
Accuracy
400µA
0.1µA
± (1.2% of rdg + 8dgts)
4000µA
1µA
40mµA
10µA
400mµA
100µA
4A
1mA
10A
10mA
Overload Protection: µA and mA ranges: F0.5A/600V fuse
4A and 10A ranges: F10A/600V fuse
Max. Input Current:
“INPUT” Terminal: 200mA
“A” Terminal: 10A
(For measurements >5A: only measure in durations less than 10 seconds,
in intervals greater than 15 minutes.)
Voltage Drop: 400µA, 40mA and 4A ranges: 40mV
4000µA, 400mA and 10A ranges: 400mV