Page 6
CONTROLS
CONTROL PANEL
1.
PUMP
–
Turns Feeder Pump ON and OFF.
2.
SET-UP
–
Feeder makes a full cycle bringing one envelope to Press. Mode Switch
(#5)
must be on
MANUAL
; Pump Switch
(#7)
must be ON and drive motor running.
3.
MODE SWITCH
–
In depressed position, activates Speed Control
(#4)
. In released
position, activates Pulse Generator and synchronizes Feeder with Press.
4.
FEEDER SPEED CONTROL
–
In
MANUAL
mode, enables operator to adjust speed
of drive motor during set-up.
5.
POWER SWITCH
–
Turns Feeder ON and OFF.
6.
FUSE
–
Drive Motor, 2 AMPS
7.
FUSE
–
Pump, 10 AMPS
VACUUM BLEED VALVE
Vacuum Bleed Valve is located on left-side Feeder Frame.
Turning it clockwise increases amount of vacuum going into
suction feet. Turning it counterclockwise decreases vacuum.
Figure
5
Figure
7
Figure
6