Page 3
INSTALLATION INSTRUCTIONS
1.
Unplug Duplicator.
2.
Remove rear right upper Side
Cover from Duplicator.
3.
Remove cross-brace bolt near
buckle control gear.
4.
Place Pulse Generator
[Fig. 2]
lower bracket over
cross-brace bolt hole and
reinstall bolt.
DO NOT
TIGHTEN
at this time.
5.
Swing Pulse Generator all the
way to the left until gears engage
and secure bolt.
6.
Route Pulse Generator cable
through large hole at rear of
Duplicator Side Frame. Use
plastic ties (P/N 123-0113) to prevent cable from entering moving parts of Duplicator.
WARNING: FAILURE TO DO THIS RESULTS IN SERIOUS DAMAGE TO
ENVELOPE FEEDER AND DUPLICATOR.
7.
Check gap between Sensor and Magnet Assembly by rotating Duplicator by hand. (
Should
be 1/32" ± 0.010"
). Adjust gap by loosening sensor mounting screws and moving bracket.
8.
Lift up Flip-up Paper Guide to accommodate Feeder.
NOTE:
If Duplicator is equipped with T-51 Head (P/N 84-101-51),
mount Guide Support Bracket on Duplicator.
a)
Remove rear hex nut securing Bail Bar Bracket to Side Frame.
b)
Place Guide Support (P/N 84-101-51) over bolt and secure in place with
nut (P/N 84-101-49).
c)
Lift Flip Guide up, swing Guide Support up and rest Flip Guide on it.
9.
Reinstall Duplicator Side Cover.
10.
Remove Bail Bar.
11.
Position Paper Guides to widest position.
NOTE:
On 8000 Series Duplicators, remove collar on inside of non-
operator’s side of
Side Guide that limits movement of Side Guides. Reinstall on outside of shaft.
This permits movement of Side Guides to a position wide enough to accommodate
Envelope Feeder.
12.
Push down Table Release Lever and move paperboard halfway down.
13.
Lift paperboard Stop Lever
[Figure 3]
and place Paperboard Stop (P/N 84-100-82) on
stud. Release lever so it rests in groove of Paper Board Stop. This prevents paperboard
from coming up and hitting Feeder.
Figure 2