APPENDIX: ALTERNATE INSTALLATION INSTRUCTIONS

Route and connect optional firebox liner backlight 

kit wiring and install lamp assemblies

NOTE: 

These instructions should be used in place of 

Route 

and connect optional firebox liner backlight kit wiring and 

install lamp assemblies

 on 

Page 6

, for fireplaces without 

backlight wiring kit routing holes as shown in 

Figure 12

 on 

Page 6

.

1. 

Route one set of three leads (white/green/black) through 

the hole in the front of the bracket (

Figure 26

).

Front of Mounting Bracket

Figure 26: Routing wires through lamp bracket

2. 

Connect the green wire to the lamp (

Figure 27

).

Figure 27: Attaching green wire to firebox liner backlight kit 

lamp, and inserting lamp into lamp bracket

3. 

Insert the lamp (with green wire attached) into bracket until 

the spring clip is engaged (

Figure 27

).

4. 

Connect the white (neutral) wire, and black (hot) wire 

(

Figure 28

).

Figure 28: Attaching black and white wires to firebox liner 

backlight kit lamp

5. 

Repeat the process in 

step 1 

through

 step 4 

for the two 

remaining lamp assemblies.

6. 

Carefully lay the firebox backlight lamp assemblies and 

wiring on the fireplace floor. The lamp assemblies will not 

be installed until the back panel is installed (in a later step).

7. 

Remove the three (3) cover plates in the lower front face 

of the back panel. Discard the cover plates, but retain the 

screws.

8. 

Insert the three (3) previously assembled lamp assemblies 

in the orientation shown (

Figure 29

). 

NOTE: 

The wires will be routed under the rear floor section 

in the next step.

9. 

Secure the lamp assemblies using the six (6) previously 

removed screws from the cover plates. 

Cover Plate

Note orientation of each 

lamp assembly.

Figure 29: Installing the lamp assemblies

NOTE: 

When installing the rear floor, route the firebox 

backlight wiring through the notches under the rear floor 

section. Be careful not to pinch or damage the wires.

Summary of Contents for Rhapsody42TEN

Page 1: ...your local distributor or dealer Figure 1 54 in DRL and Rhapsody linear gas fireplaces with designer floor kit and Illusion Cityscape firebox liner kit both in black porcelain HEARTH PRODUCTS KITS AND...

Page 2: ...RSHGL RBLK Reflective Blue H8424 CRSHGL RBLU Platinum H8413 CRSHGL P Goldfinger H8538 CRSHGL GF Copper H8539 CRSHGL C Table 3 Required Media Kits OPTIONAL ACCESSORIES Firebox Liner Backlight Kits 1 Le...

Page 3: ...Take care not to damage the glass 3 Set aside the screws and glass door assembly in a secure location for later reinstallation Glass Door Assembly Figure 3 Removing the glass door assembly Remove baff...

Page 4: ...lame SimFlame Module Fan Control Module Plug blower into FAN port Plug lights into AUX OUT port Figure 8 Connecting the lights and blower 4 Route the lighting wiring up through the access opening and...

Page 5: ...nal firebox liner backlight kit wiring and install lamp assemblies on Page 10 1 Determine whether the firebox rear ledge has backlight wire routing holes Figure 12 CONNECTION AND ROUTE WIRING FOR OPTI...

Page 6: ...ly removed screws from the cover plates Figure 16 Backlight Wire Routing Holes Figure 12 Routing wiring 2 If the firebox rear ledge has backlight wire routing holes proceed with the instructions in Ro...

Page 7: ...edge Tab Side Panel Center Lower Tab Figure 17 Installing the rear floor section Install front floor section from required floor kit 1 Engage the lower front lip of the front floor section under the l...

Page 8: ...rd the door Figure 23 2 Gently push the lower edge of the bezel to attach the bezel lower flange to the lower edge of the glass door frame Bezel Upper Flange Bezel Lower Flange CROSS SECTION Glass Doo...

Page 9: ...Z 1PH Junction Box Field Wired Factory Wired Power Supply Unswitched Figure 24 Junction Box Wiring Pilot Tube COLOR CODE B BLACK BB BROWN W BLACK STRIPE BG BROWN W GREEN STRIPE BL BLUE BR BROWN G GREE...

Page 10: ...lamp Figure 27 Figure 27 Attaching green wire to firebox liner backlight kit lamp and inserting lamp into lamp bracket 3 Insert the lamp with green wire attached into bracket until the spring clip is...