MHD35 Series Direct-Vent Gas Fireplaces
58
MAINTENANCE
Refer to the
Maintenance Schedule
on
Page 60
for maintenance tasks, procedures, frequency, and a listing of by
whom the tasks should be performed. Always verify proper fi replace operation after servicing.
WARNING
Turn OFF gas and electrical power to the fi replace and allow it to cool before cleaning or
servicing the appliance.
CAUTION
Wear gloves and safety glasses for protection while doing required maintenance.
Verify proper operation after servicing.
S’assurer que l’appareil fonctionne adéquatement une fois l’entretien terminé.
Always turn OFF gas before cleaning. Before relighting, refer to the lighting instructions in this manual.
Instructions are also found on a pull-out panel located in the control compartment.
Always keep the appliance area clear and free from combustible materials, gasoline and other fl ammable liquids.
NOTE:
Prior to the fi rst use of the fi replace and each burn season and periodically during the burn season, inspect the
horizontal termination for debris such as bird nests, leaves, paper or branches. Remove any items from the surfaces of the
termination prior to use. Also be aware of shrubs and plantings that may encroach on the termination.
Inspecting the venting system
The fi replace and venting system should be thoroughly inspected before initial use and at least annually by a qualifi ed
service technician. Inspection should include ensuring that exhaust or intake passages are unobstructed and vent
components are properly assembled and not damaged.
The homeowner must contact a qualifi ed service technician at once if any abnormal condition is observed.
If the venting system is disassembled for any reason, a qualifi ed service technician should follow vent installation
instructions for proper reassembly and proper sealing of the venting system components. However, more frequent
periodic inspections and cleanings should be performed by the homeowner.
NOTE:
Prior to the fi rst use of the fi replace and each burn season and periodically during the burn season, inspect
the horizontal termination for debris such as bird nests, leaves, paper or branches. Remove any items from
the surfaces of the termination prior to use. Also be aware of shrubs and plantings that may encroach on the
termination.
Inspecting the burner fl ame appearance
Periodically inspect the burner and pilot fl ame. Ensure that the burner fl ame appearance resembles the fl ame shown
in
Figure 38
on
Page 40
and as described in
Flame Appearance and Sooting on
Page 41
. Any necessary burner
fl ame adjustments must be performed by qualifi ed personnel only
(
Page 41
)
. Refer to
Page 40
for more information
about the pilot fl ame appearance. Contact a qualifi ed service technician at once if any abnormal condition is
observed.
Cleaning the glass door
WARNING
Do not use abrasive cleaners on glass. Never clean the glass when it is hot.
Clean the glass during the
Burn-in Period
, and then only when necessary and when the fi replace is cool. Wipe the
surface with a clean, dampened, soft cloth. Follow with a dry, soft towel as desired. Take care not to scratch the glass
surface. Periodically, remove any build-up caused by the following:
•
During start-up, it is normal for condensation to form on the inside of the glass (this condensation and fog will
usually disappear in a few minutes). The moisture can cause lint, dust and other airborne particles to cling to the
glass surface.
•
Initial curing of the high temperature paint and burning off of lubricants used in the manufacturing process may
result in a fi lm on the glass.
•
A white coating may form on the glass as a result of impurities and minerals in the fuel.
Clean the glass two or three times each heating season, depending on the circumstances present. The following
cleaning solutions are approved for use:
•
Non-ammonia based glass cleaner
•
50/50 mixture of white vinegar / water
• Gas
fi replace/stove glass cleaner