background image

Astria.us.com

900635-00A

10

Installing Batteries in Battery pack 

1.  Remove access cover on battery pack.
2.  Install 4 AA batteries, included, into battery pack following 

positive and negative directions.

3.  Replace access cover on battery pack.
4.  Place battery pack next control valve away from the burner.

Installing Batteries in Handheld Remote Control

1.  Remove battery cover on back of remote control.
2.  Install  supplied A23/12V  battery  following  positive  and 

negative directions.
3.  Replace battery cover onto remote control.

Gas Meter

Figure 15 - Checking Gas Joints (Natural Gas Only)

Control Valve 

Location

Equipment Shutoff Valve

INSTALLATION

Continued

1.  Open equipment shutoff valve

 (see 

Figure 13, Page 9

)

.

2.  Open main gas valve located on or near gas meter for 

natural gas or open propane/LP supply tank valve.

3.  Make sure control knob of appliance is in the OFF position.
4.  Check all joints from gas meter to equipment shutoff valve 

for natural gas or propane/LP supply to equipment shutoff 

valve for propane/LP

 (see 

Figure 14, Page 9 or Figure 

15, Page 10

)

. Apply noncorrosive leak detection fluid to all 

joints. Bubbles forming show a leak. 

5.  Correct all leaks at once.
6.  Light appliance 

(see Operation, 

Page 14

)

. Check all other 

internal joints for leaks.

7.  Turn off appliance 

(see To Turn Off Gas to Appliance, 

Page 

14

).

INSTALLING BATTERIES IN HAND HELD REMOTE 

CONTROL AND BATTERY PACK 

Figure 16 - MF Series Burner System- Log Compatibility 

Chart

INSTALLING LOGS AND VOLCANIC STONE

 

WARNING: Failure to position the parts in 

accordance with these diagrams or failure to 

use only parts specifically approved with this 

appliance may result in property damage or 

personal injury. 

 

CAUTION: After installation and periodically 

thereafter, check to ensure that no flame comes 

in contact with any log. With appliance set to 

Hi, check to see if flames contact any log. If 

so, reposition logs according to log installation 

instructions in this manual. Flames contacting 

logs will create soot.

LOG PLACEMENT

It is very important to install these logs exactly as instructed. 

Do not modify logs. Only use logs supplied with appliance or 

as identified for use with the appliance as shown in 

Figure 18

.

NOTE:

 Each log includes an identifying number cast in the 

log. Look at each log when placing them on the burner system 

to be certain it is correct.

1.  Find  the  right  front  log  (SouthernComfort30  or 

ShadyHollow30 inch models: D-019 or SouthernComfort36 

and ShadyHollow36 inch models: D-027). See 

Figures 17, 

17A, 17B, 

and

 17C

 for reference. The log has a rectangular 

shape on the bottom that fits against the lip on the black 

metal base, the square grate, and the round tube burner. 

Slide the log in place as shown in Figures.

MF SERIES BURNER SYSTEM

LOG COMPATIBILITY CHART

Burner System Model

Refractory Concrete Logs

For Use With This Burner

System

MAGNIFLAMEOD30NE, 

MAGNIFLAMEOD30PE

SOUTHERNCOMFORT30A/B
SOUTHERNCOMFORT36A/B

SHADYHOLLOW30A/B
SHADYHOLLOW36A/B

Summary of Contents for MAGNIFLAMEOD30NE

Page 1: ...og Appliance Remote Ready Log Set And Burner System Models Models MAGNIFLAMEOD30NE MAGNIFLAMEOD30PE SOUTHERNCOMFORT30A B SOUTHERNCOMFORT36A B SHADYHOLLOW30A B SHADYHOLLOW36A B P N 900635 00 REV A 01 2...

Page 2: ...nt children from turning on burners with remote WARNING Improper installation adjust ment alteration service or maintenance can cause injury or property damage Refer to this manual for correct install...

Page 3: ...ance Page 16 8 Before using furniture polish wax carpet cleaner or similar products turn appliance off If heated the vapors from these products may create a white powder residue within burner box or o...

Page 4: ...appliance Follow all local codes NOTICE State or local codes may only allow operation of this appliance in a vented con figuration Check your state or local codes WARNING Make sure the selector switch...

Page 5: ...8 up for all models If noncom bustible material is less than 12 you must install the fireplace hood accessory See Figure 3 for minimum clearances If Using Mantel You must have noncombustible material...

Page 6: ...ide of Mantel Top of Fireplace Opening Underside of Mantel Shelf 12 A 18 20 22 24 All minimum distances are in inches 2 1 2 6 8 10 Mantel Shelf Minimum Noncombustible Material 8 Min 12 15 18 20 2 1 2...

Page 7: ...provided electric drill with 3 16 masonry drill bit 1 Apply pipe joint sealant lightly to male threads of the 1 2 NPT side of gas fitting elbow provided and connect to inlet side of gas control Remov...

Page 8: ...ealant that is resistant to liquid petroleum LP gas We recommend that you install a sediment trap in supply line as shown in Figure 12 Locate sediment trap where it is within reach for cleaning Instal...

Page 9: ...er 5 W C to 10 5 W C Pressure 3 Pressurize supply piping system by either opening pro pane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural ga...

Page 10: ...CONTROL AND BATTERY PACK Figure 16 MF Series Burner System Log Compatibility Chart INSTALLING LOGS AND VOLCANIC STONE WARNING Failure to position the parts in accordance with these diagrams or failur...

Page 11: ...hadyHollow24 inch models D 060 or SouthernComfort30 and ShadyHollow30 inch models D 018 or SouthernComfort36 and ShadyHollow36 inch models D 026 See Figures 18 18A and 18B Figure 18A shows how the log...

Page 12: ...he front left log SouthernComfort30 and ShadyHol low30 inch models D 017 or SouthernComfort36 and ShadyHollow36 inch models D 025 See Figures 19 19A and 19B The log has a rectangular stand off on the...

Page 13: ...Split Log D 021 Middle Split Log D 063 D 021 or D 028 Square Peg Square Grate Log Notch Figure 23 Installing Front Top Log Front Top Log D 024 Rectangular Peg Right Split Crossover Log D 022 Middle Sp...

Page 14: ...loor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Fol...

Page 15: ...mote system is ready for use Pushing and holding the LEARN button for 6 seconds will result in clearing the transmitter security code from the module s memory The module will make three long beeps in...

Page 16: ...er for dust and dirt see Figure 31 3 Blow air through the ports slots and holes in the burner 4 Check injector holder located at end of burner tube again Remove any large particles of dust dirt lint o...

Page 17: ...ge Orange Orange Red Brown Black Solenoid White Brown Brown Green Igniter Pilot I S AUX AF 5000MOD AF 4000 AF 4000B P Control Module Black Black Option Battery Red SWI SWI GND Black Red HI LO Main Bla...

Page 18: ...ct igniter cable 2 Free igniter cable if pinched by any metal or tubing Keep igniter cable dry 3 Replace igniter 4 Replace igniter 5 Adjust igniter wires as shown in Figure 28 on Page 15 Replace ignit...

Page 19: ...air is re moved from line Have gas line checked by local natural or pro pane LP gas company 2 Observe minimum installation clearances see Pages 9 11 3 Clean burner see Cleaning and Maintenance Page 16...

Page 20: ...Warning state ment at top of page 2 Control valve or gas control de fective 1 The module s internal tempera ture is too high 1 The burner did not successfully ignite 1 Gas leak See Warning state ment...

Page 21: ...f the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation or application of this appliance please cont...

Page 22: ...ia us com 900635 00A 22 PARTS MODELS MAGNIFLAMEOD30NE AND MAGNIFLAMEOD30PE 1 2 4 5 6 7 8 9 10 11 12 13 15 16 18 19 20 21 23 24 25 26 22 17 14 8 3 Cat No Model F0561 MAGNIFLAMEOD30NE F0563 MAGNIFLAMEOD...

Page 23: ...ech 1 J8244 Screw 00 Min Rate Skytech 1 15 J8238 Cap 3 8 Compression 1 16 J4833 T Fitting Brass 3 8 Tube x 3 8 NPT 1 17 J6532 Grate MF42 Stainless Steel 1 J8237 Grate MF48 Stainless Steel 1 18 J4711 F...

Page 24: ...ssembly The next two numbers indicate the set size 2 6 3 9 1 7 8 5 4 KEY NO PART NO LOG ID NO PART NO LOG ID NO DESCRIPTION QTY 1 J6516 D 019 J6527 D 027 Log Front Right 1 2 J6517 D 018 J6528 D 026 Lo...

Page 25: ...ted under Replacement Parts on Page 21 of this manual KEY NO CAT NO Log Id CAT NO Log Id DESCRIPTION QTY 1 J8253 D 019 J8259 D 027 Log Front Right 1 2 J8254 D 018 J8260 D 026 Log Back Left 1 3 J8255 D...

Page 26: ...___________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _______...

Page 27: ...damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions pr...

Page 28: ...er Appliance serial number Date appliance was Installed Type of gas appliance uses Dealer name IHP reserves the right to make changes at any time without notice in design materials specifications pric...

Reviews: