background image

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, 

where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the 

rating plate. This appliance is not convertible for use with other gases.

WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built 

fireplace or in a listed ventless firebox enclosure. It is design-certified for these installations in accordance 

with ANSI Z21.11.2. Exception: DO NOT install this appliance in a factory-built fireplace that includes 

instructions stating it has not been tested or should not be used with unvented gas logs.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions 

for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation 

section on 

Page 6

 of this manual.

Installation and Operation Instructions

Unvented (Vent-Free) Gas Log Heater

Models

PFS

®

US

Report No. F09-129

EOS18MN

EOS18MP

P/N 126854-01   REV. 

 

F  03/2019

For use with log sets

 

ChestnutH18
ChestnutH24

CarolinaOak18
CarolinaOak24

P126854-01

       WARNING:
FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious injury, death, or property damage.

-   Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance.

 -  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance. 

•  Do not touch any electrical switch; do not use any phone in your building. 

•  Leave the building immediately.

• Immediately call your gas supplier from a neighbor’s phone.  Follow the gas supplier’s instructions. 

•  If you cannot reach your gas supplier, call the fire department.

 -  Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Summary of Contents for EOS18MN

Page 1: ...alled Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on Page 6 of this manual Installation and Operation Instructions Unven...

Page 2: ...prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale n...

Page 3: ...uld be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition Heater will remain hot for a time after shutdown Allow surface to cool before touching...

Page 4: ...ot follow the instructions in Cleaning and Maintenance Page 19 11 Before using furniture polish wax carpet cleaner or similar products turn appliance off If heated the vapors from these products may c...

Page 5: ...ith 527 CMR 30 Installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts The flexible gas line connector used shall not exceed 36 inches 92 centimet...

Page 6: ...applicable local codes Read the following instructions to en sure proper fresh air for this and other fuel burning appliances in your home Confined and Unconfined Space The National Fuel Gas Code ANS...

Page 7: ...all connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion a...

Page 8: ...rmanently closed at time of appliance installation WARNING Seal any fresh air vents or ash clean out doors located on floor or wall of fireplace If not draftingmaycausepilotoutageorsooting Useaheat re...

Page 9: ...ble material is less than 12 you must install the fireplace hood accessory for all models See Figure 5 for minimum clearances If Using Mantel You must have noncombustible material s above the fireplac...

Page 10: ...en Using a Hood If minimum clearances in Figure 6 are not met you must have a hood When using a hood there are still certain minimum mantel clearances required Follow minimum clearances shown in Figur...

Page 11: ...ue opening will be maintained at all times IMPORTANT Make sure the heater burners are level If heater is not level heater will not work properly Installation Items Needed hardware package provided wit...

Page 12: ...ch For propane LP units the installer must supply an external regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 14 of water If...

Page 13: ...y not run properly CAUTION Avoid damage to regulator Hold gas regulator with wrench when connecting it to gas pip ing and or fittings WARNING Test all gas piping and connections internal and external...

Page 14: ...sediagramsorfailuretouseonlyparts specifically approved with this heater may result in property damage or personal injury CAUTION After installation and periodically thereafter check to ensure that no...

Page 15: ...19 Front log has cut outs for the fingers of the grate to fit into Figure 20 Installing Left Center and Right Crossover Logs Right Crossover Log Left Crossover Log Center Crossover Log Square Peg on R...

Page 16: ...ont Log Rear Log Log Notch Figure 25 Installing Middle Log Figure 26 Installing Top Left Log Figure 27 Final assembly 5 Place the top middle log onto the rear middle logs as shown in Figure 25 Make su...

Page 17: ...obstructions across opening of fireplace Youmustoperatethisheaterwithafireplacescreen inplace Makesurefireplacescreenisclosedbefore running heater NOTICE During initial operation of new heater burn in...

Page 18: ...h selector switch if optional re mote control is used to the ON position to light burners NOTE AUTO is only functional when using GWMT1 or GWMS2 optional accessories 11 Set flame adjustment knob to an...

Page 19: ...amount of air to mix with the gas This provides a clean burning flame Keep these holes clear of dust dirt lint and pet hair Clean these air inlet holes prior to each heating season Blocked air holes...

Page 20: ...es should be open with yellow flame present All round burner flame holes should be open with a small blue flame present Some burner flame holes may become blocked by debris or rust with no flame prese...

Page 21: ...pilot is clogged 7 Gas regulator setting is not correct 1 Turn on gas supply or open equipment shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT posi tion 4 Co...

Page 22: ...ntrol knob to HI position when burners are cold 2 Air in gas line 3 Air passageways on heater blocked 4 Dirty or partially clogged burner orifice s 1 TurncontrolknobtoLOpositionandletwarm up for a min...

Page 23: ...ilable 2 Low line pressure 3 ODS pilot is partially clogged 1 Open window and or door for ventilation 2 Contact local natural or propane LP gas company 3 Clean ODS pilot see Cleaning and Main tenance...

Page 24: ...O MODEL F0155 EOS18MN F0156 EOS18MP WARNING Failure to position the parts in accor dancewiththesediagramsorfailuretouseonlyparts specifically approved with this heater may result in property damage or...

Page 25: ...ce 111 1 J3617 Orifice 073 1 7 J3635 Pilot Tube 1 J3637 Pilot Tube 1 8 J3654 Pilot Regulator 1 9 J3660 Tube 1 10 J3830 Pilot ODS LP 1 J3831 Pilot ODS NG 1 11 J3836 Gas Valve NG 1 J3837 Gas Valve LP 1...

Page 26: ...1 5 J6112 Center Crossover Log 1 J6118 Center Crossover Log 1 6 J6113 Right Front Crossover Log 1 J6119 Right Front Crossover Log 1 C a r o l i n a O a k 1 8 C a r o l i n a O a k 2 4 4 5 1 3 6 2 CHE...

Page 27: ...mplete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at ti...

Page 28: ...ve fireplace Fits open ings 28 to 48 wide F1764 GA6050 Hood Adjustable Flat Black DECORATIVE ASH BED CONTROL COVER KIT F1759 CDABKA 6 KIT DECORATIVE ASH BED 6PK F0246 CDABKA Decorative Ash Bed Control...

Page 29: ...L KIT For all Remote Ready Models Allows the burner system to be operated in a manually or thermostatically controlled mode Remote is programmable for your convenience and has a large bright LCD Touch...

Page 30: ...____________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________...

Page 31: ...mage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions prov...

Page 32: ...al distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126854 01 Rev F 03 2019 1769 East Lawrence Street Russellville AL 35654 Astria us com Record the foll...

Reviews: