Astria.us.com
126854-01F
10
Minimum
Noncombustible
Material
8"
Min.
12" 15" 18" 20"
2½"
6"
8"
10"
12"
Distances to
Underside of
Mantel
Hood
(GA6050)
Top of
Fireplace
Opening
Underside
of Mantel
Shelf
Mantel Shelf
Figure 7 - Minimum Mantel Clearances When Using Hood
FLOOR CLEARANCES
A. If installing appliance on the floor level, you must maintain the
minimum distance of 14" to combustibles
(see
Figure 8
).
B. If combustible materials are less than 14" to the fireplace, you
must install appliance at least 5" above the top surface of com-
bustible flooring including tile and carpet
(see
Figure 9
).
14"
Min.
Combustible
Material
Noncombustible Material
Figure 8 - Minimum Fireplace Clearances If Installed at Floor
Level
Figure 9 - Minimum Fireplace Clearances Above Combustible
Flooring
Hearth
5"
Min.
Combustible
Material
Determining Minimum Mantel Clearance When Using a Hood
If minimum clearances in
Figure 6
, are not met, you must have a
hood. When using a hood there are still certain minimum mantel
clearances required. Follow minimum clearances shown in
Figure
7
when using hood.
NOTICE: Surface temperatures of adjacent walls and
mantels become hot during operation. Walls and
mantels above the firebox may become hot to the
touch. If installed properly, these temperatures meet
the requirement of the national product standard. Fol-
low all minimum clearances shown in this manual.
Notice: If your installation does not meet the minimum
clearances shown, you must do one of the following:
• operate the logs only with the flue damper open
• raise the mantel to an acceptable height
• remove the mantel
Minimum
Noncombustible
Material
Minimum Non-
Combustible
Material Height
Distances to
Underside of
Mantel
Top of
Fireplace
Opening
Underside of
Mantel Shelf
Mantel Shelf
12"
8"
(A)
18"
8"
20"
14"
22"
17"
24"
20"
Log Set
24" Models
18" Model
2 ½"
6"
8"
10"
Figure 6 - Minimum Mantel Clearances Without Using Hood
INSTALLATION
Continued