1

26896

-01A

4

SAFETY INFORMATION

Continued

You must operate this log set 

with a fireplace doors or screen 

in place and fully closed. Un-

less provided by other means, 

screens shall have openings for 

introduction of combustion air.

Keep the appliance area clear 

and free from combustible ma-

terials, gasoline and other flam

-

mable vapors and liquids.

1.  This appliance is only for use with the type of 

gas indicated on the rating plate. This appliance 

is not convertible for use with other gases. 

2.  Do not place propane/LP supply tank(s) in

-

side any structure. Locate propane/LP supply 

tank(s) outdoors (propane/LP units only).

3.  If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not use 

any phone in your building

• immediately call your gas supplier from a 

neighbor’s phone. Follow the gas supplier’s 

instructions

• if you cannot reach your gas supplier, call 

the fire department

4.  Never install log set

• in a recreational vehicle

• where curtains, furniture, clothing or other 

flammable objects are less than 42" from 

the front, tip or sides of the log set

• in high traffic areas

• in windy or drafty areas

5.  Before installing in a solid fuel burning fireplace, 

the chimney flue and firebox must be cleaned 

of soot, creosote, ashes and loose paint by a 

qualified chimney cleaner. Creosote will ignite if 

highly heated. Inspect chimney flue for damage. 

If damaged, repair flue before operating the log 

set.

6.  Do not burn solid-fuel in the fireplace after 

installing the log set. Do not use this log set 

to cook food or burn paper or other objects.

7.  This log set is designed to be smokeless. If logs 

ever appear to smoke, turn off appliance and call 

a qualified service person. 

Note:

 During initial 

operation, slight smoking could occur due to log 

curing and burning of manufacturing residues. 

You may wish to add more ventilation by opening 

a window.

8.  To  reduce  the  creation  of  soot,  follow  the 

instructions  in 

Cleaning and Maintenance

page 14.

9.  Before  using  furniture  polish,  wax,  carpet 

cleaner or similar products, turn the log set off. 

If heated, the vapors from these products may 

create a white powder residue within burner 

box or on adjacent walls or furniture.

10.  Do not run the appliance

• where flammable liquids or vapors are used 

or stored

• under dusty conditions

11.  Do not use the log set if any part has been 

exposed to or under water. Immediately call 

a qualified service technician to inspect the 

log set and to replace any part of the control 

system and any gas control which has been 

under water. 

12.  Do  not  operate  the  appliance  if  any  log  is 

broken. Do not operate the log set if a log is 

chipped (dime-sized or larger). 

13.  Turn  the  appliance  off  and  let  cool  before 

servicing or repairing. Make sure the selector 

switch is in the OFF position. Only a qualified 

service person should install, service or repair 

log set.

14.  To  prevent  performance  problems,  do  not 

use propane/LP fuel tank of less than 100 lb. 

capacity (propane/LP units only).

15.  The installation of these appliances in manu

-

factured  homes  in  the  U.S.  must  conform 

with the Manufactured Home Construction 

and  Safe

ty Standard, Title 24 CFR, Part 

3280

,  in  the  United  States,  or  when  such 

a standard is not applicable, 

Manufactured 

Home Installation Standard, ANSI/NCSBCS 

A225.1/NFPA 501A.

16. Provide  adequate  clearances  around  air 

openings.

LOCAL CODES

Install and use this appliance with care. Follow 

all local codes. In the absence of local codes, use 

the latest edition of 

The National Fuel Gas Code 

ANSI Z223.1/NFPA 54

*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note

: Where  listed  vented  decorative  logs  are 

required, thermostat operation

Summary of Contents for Arcadia18MN

Page 1: ...fer to the National Fual Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 for Combustion and Ventilation WARNING If the information in these instructions is not followed exactly a fire or explosion may resul...

Page 2: ...nce may be in stalled in an aftermarket permanently located manufactured mobile home where not prohib ited by local codes This appliance is only for use with the type of gas indicated on the rating pl...

Page 3: ...ay be present even though no odor exists Make certain you read and understand all warn ings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Any cha...

Page 4: ...to log curing and burning of manufacturing residues Youmaywishtoaddmoreventilationbyopening a window 8 To reduce the creation of soot follow the instructions in Cleaning and Maintenance page 14 9 Befo...

Page 5: ...CSA 2 26a 2000 as a vented decorative appliance SAFETY DEVICE This log set has a pilot with an Oxygen Depletion Sensing ODS safety shutoff system The ODS pilot shuts off the log set if there is not en...

Page 6: ...nstalled only in a solid fuel burning or UL127 factory built fireplace with a working flue and constructed of noncombustible material The fireplace must include a working flue and venting system with...

Page 7: ...aged Raise fireplace floor with noncombustible mate rial Makesurematerialissecure CAUTION Do not pick up the log set assembly by the logs This could damage log set Only handlebaseassemblybygrates IMPO...

Page 8: ...g gas pressure log set regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 6 Pointing the vent down protects it from freezing rain or sleet Figure 6...

Page 9: ...n or near gas meter for natural gas or using compressed air INSTALLATION Continued Check your building codes for any special re quirements for locating equipment shutoff valve to fireplaces Apply pipe...

Page 10: ...in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service tech nician or gas supplier Force or attempted repair may r...

Page 11: ...gh 8 9 Slightly push in and turn control knob coun terclockwise to the ON position 10 Wait one minute and switch selector switch to the ON position to light burners 11 Set flame adjustment knob to any...

Page 12: ...al OPTIONAL HAND HELD REMOTE CONTROL OPERATION 1 After lighting let pilot flame burn for about one minute Turn control knob to ON position Adjust flame adjustment knob anywhere between HI and LO Set t...

Page 13: ...uld be blue and have no yellow or orange color Figure 15 Incorrect Pilot Flame Pattern Your Pilot May Differ from Pilots Shown Figure 14 Correct Pilot Flame Pattern Your Pilot May Differ from Pilots S...

Page 14: ...the appliance serviced Keep area around log set clean and clear of de bris Periodically inspect burner for foreign matter blocking air inlet and flame holes Once every year a qualified agency or cert...

Page 15: ...n while in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free...

Page 16: ...om gas control 1 Manifold pressure is too low 2 Burner orifice clogged 1 Burner orifice is clogged or damaged 2 Damaged burner 3 Gas regulator defective REMEDY 1 Press in control knob fully 2 After OD...

Page 17: ...furniture polish wax carpet cleaners etc turn into white powder residue 1 Battery is not installed Battery power is low 1 Metal expanding while heating or contracting while cooling REMEDY 1 Check burn...

Page 18: ...e Warning statement at top of page 1 Not enough fresh air is avail able 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve or gas cont...

Page 19: ...ctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory ACCESSORIES Purchase these log set accessories from your local dealer If the...

Page 20: ...CADIA18MN AND ARCADIA18MP 19 4 3 5 6 4 4 7 1 20 8 20 18 9 2 10 13 10 4 11 12 15 14 17 16 Installed in BTB Models Only Log Set Ceramic Burner and Ramp Pan are Ordered as an Assembly Air Shutter Install...

Page 21: ...4 Orifice 1 8 111807 01 Valve NG 1 111807 02 Valve LP 1 9 116791 01 Valve Bracket 1 10 111435 01 Electronic Ignitor 1 11 103784 01 Control Knob Extension 1 12 103784 02 Control Knob Extension 1 13 099...

Page 22: ...ARCADIA24MN AND ARCADIA24MP 1 20 8 9 13 19 18 17 16 10 4 4 11 12 15 14 Installed in BTB Models Only 3 5 6 4 4 7 Log Set Ceramic Burner and Ramp Pan are Ordered as an Assembly Air Shutter Installation...

Page 23: ...Orifice 1 8 111807 01 Valve 1 111807 02 Valve 1 9 116791 01 Valve Bracket 1 10 111435 01 Electronic Ignitor 1 11 103784 01 Control Knob Extension 1 12 103784 02 Control Knob Extension 1 13 099998 01...

Page 24: ...RANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ______________________...

Page 25: ...use damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instruction...

Page 26: ...NOTES...

Page 27: ...NOTES...

Page 28: ...126896 01 Rev A 2 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126896 01...