Astria Fireplaces Arcadia18MN Installation And Operation Instructions Manual Download Page 25

25

Printed in U.S.A. © 2013  Innovative Hearth Products LLC

P/N 900201-00, Rev. NC  12/2013

Innovative Hearth Products

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Innovative Hearth Products

Astria™ Brand Gas Log Set & Outdoor Gas Fire Pit

Limited Three Year Warranty

THE WARRANTY

Innovative Hearth Products Limited Three Year Warranty ("IHP") warrants your Astria™ brand Gas Log Set or Outdoor Gas Fire Pit ("Product") to be free from defects in 

materials and workmanship at the time of manufacture. The logs and grate carry the Limited Three Year Warranty. After installation, if covered components manufactured 

by IHP are found to be defective in materials or workmanship during the Limited Three Year Warranty period and while the Product remains at the site of the original instal-

lation, IHP will, at its option, repair or replace the covered components. If repair or replacement is not commercially practical, IHP will, at its option, refund the purchase 

price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing 

or replacing such components. THERE ARE EXCLUSIONS AND LIMITATIONS to this Limited Three Year Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of installation. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of 

product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This Limited Three Year Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be  purchased through a listed supplier of IHP and proof of purchase must be 

provided. The following do not carry the Limited Three Year Warranty but are warranted as follows:

Gas components

 – Repair or replacement for one year from the date of installation.

Remote control

 – Repair or replacement for one year from the date of installation.

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component.

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 

natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 

and could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 

(d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.

This Limited Three Year Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are 

not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 

any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 

replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular 

use or purpose, and there is no implied condition of fitness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this Limited Three Year Warranty. The duration of any implied warranty is limited to the duration of this expressed 

warranty.

No one is authorized to change this Limited Three Year Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and 

provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of 

this Limited Three Year Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this Limited Three Year Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefits and advantages described in this Limited Three Year Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP. 

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. 

IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without first obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.ASTRIA.US.COM.

Summary of Contents for Arcadia18MN

Page 1: ...fer to the National Fual Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 for Combustion and Ventilation WARNING If the information in these instructions is not followed exactly a fire or explosion may resul...

Page 2: ...nce may be in stalled in an aftermarket permanently located manufactured mobile home where not prohib ited by local codes This appliance is only for use with the type of gas indicated on the rating pl...

Page 3: ...ay be present even though no odor exists Make certain you read and understand all warn ings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Any cha...

Page 4: ...to log curing and burning of manufacturing residues Youmaywishtoaddmoreventilationbyopening a window 8 To reduce the creation of soot follow the instructions in Cleaning and Maintenance page 14 9 Befo...

Page 5: ...CSA 2 26a 2000 as a vented decorative appliance SAFETY DEVICE This log set has a pilot with an Oxygen Depletion Sensing ODS safety shutoff system The ODS pilot shuts off the log set if there is not en...

Page 6: ...nstalled only in a solid fuel burning or UL127 factory built fireplace with a working flue and constructed of noncombustible material The fireplace must include a working flue and venting system with...

Page 7: ...aged Raise fireplace floor with noncombustible mate rial Makesurematerialissecure CAUTION Do not pick up the log set assembly by the logs This could damage log set Only handlebaseassemblybygrates IMPO...

Page 8: ...g gas pressure log set regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 6 Pointing the vent down protects it from freezing rain or sleet Figure 6...

Page 9: ...n or near gas meter for natural gas or using compressed air INSTALLATION Continued Check your building codes for any special re quirements for locating equipment shutoff valve to fireplaces Apply pipe...

Page 10: ...in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service tech nician or gas supplier Force or attempted repair may r...

Page 11: ...gh 8 9 Slightly push in and turn control knob coun terclockwise to the ON position 10 Wait one minute and switch selector switch to the ON position to light burners 11 Set flame adjustment knob to any...

Page 12: ...al OPTIONAL HAND HELD REMOTE CONTROL OPERATION 1 After lighting let pilot flame burn for about one minute Turn control knob to ON position Adjust flame adjustment knob anywhere between HI and LO Set t...

Page 13: ...uld be blue and have no yellow or orange color Figure 15 Incorrect Pilot Flame Pattern Your Pilot May Differ from Pilots Shown Figure 14 Correct Pilot Flame Pattern Your Pilot May Differ from Pilots S...

Page 14: ...the appliance serviced Keep area around log set clean and clear of de bris Periodically inspect burner for foreign matter blocking air inlet and flame holes Once every year a qualified agency or cert...

Page 15: ...n while in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free...

Page 16: ...om gas control 1 Manifold pressure is too low 2 Burner orifice clogged 1 Burner orifice is clogged or damaged 2 Damaged burner 3 Gas regulator defective REMEDY 1 Press in control knob fully 2 After OD...

Page 17: ...furniture polish wax carpet cleaners etc turn into white powder residue 1 Battery is not installed Battery power is low 1 Metal expanding while heating or contracting while cooling REMEDY 1 Check burn...

Page 18: ...e Warning statement at top of page 1 Not enough fresh air is avail able 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve or gas cont...

Page 19: ...ctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory ACCESSORIES Purchase these log set accessories from your local dealer If the...

Page 20: ...CADIA18MN AND ARCADIA18MP 19 4 3 5 6 4 4 7 1 20 8 20 18 9 2 10 13 10 4 11 12 15 14 17 16 Installed in BTB Models Only Log Set Ceramic Burner and Ramp Pan are Ordered as an Assembly Air Shutter Install...

Page 21: ...4 Orifice 1 8 111807 01 Valve NG 1 111807 02 Valve LP 1 9 116791 01 Valve Bracket 1 10 111435 01 Electronic Ignitor 1 11 103784 01 Control Knob Extension 1 12 103784 02 Control Knob Extension 1 13 099...

Page 22: ...ARCADIA24MN AND ARCADIA24MP 1 20 8 9 13 19 18 17 16 10 4 4 11 12 15 14 Installed in BTB Models Only 3 5 6 4 4 7 Log Set Ceramic Burner and Ramp Pan are Ordered as an Assembly Air Shutter Installation...

Page 23: ...Orifice 1 8 111807 01 Valve 1 111807 02 Valve 1 9 116791 01 Valve Bracket 1 10 111435 01 Electronic Ignitor 1 11 103784 01 Control Knob Extension 1 12 103784 02 Control Knob Extension 1 13 099998 01...

Page 24: ...RANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ______________________...

Page 25: ...use damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instruction...

Page 26: ...NOTES...

Page 27: ...NOTES...

Page 28: ...126896 01 Rev A 2 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126896 01...