IMPORTANT: The instruction manual you are holding includes essential information on the safety measures to be 

implemented for installation and start-up. Therefore, the installer as well as the user must read the instructions 

before beginning installation and start-up.

Keep this manual for future reference.

To achieve optimum performance of the LumiPlus Flexi, follow the instructions provided below:

1. VERIFY THE CONTENTS OF THE PACKING:

- LumiPlus Flexi. 
- Bag of accessories: FlexiNiche cable gland, FlexiRapid cable gland, 1 seal, 1 O-ring seal, gasket, cable and mounting 

screws (1 for screwing the spotlight to the fac 3 for screwing the cable gland).

- Warranty booklet.
- Instruction manual.

MODEL AVAILABLE ACCORDING TO CHARACTERISTICS

LumiPlus V2 RGB DMX

71208

2. GENERAL CHARACTERISTICS:

LumiPlus Flexi has been designed to be used fully submerged in fresh water. It is a Class III electric apparatus with very 
low safety voltage 

(12 V with alternating current)

. LumiPlus Flexi is class 116, in accordance with standard EN 50065.

LumiPlus Flexi complies with IPX8 degree of protection at a nominal immersion depth of 2 m. 
LumiPlus Flexi complies with international safety standards for lights, especially the EN 60598-2-18 standard: LIGHTS 
PART 2: SPECIFIC REQUIREMENTS SECTION 18 LIGHTS FOR SWIMMING POOLS AND SIMILAR APPLICATIONS.
The manufacturer is not responsible in any circumstances for assembly, installation or start-up of any electric compo-
nents which have been inserted or handled at locations other than its own premises.

3. INSTALLATION:

• To correctly light a swimming pool we recommend you: 
Install a LumiPlus Flexi V2 for every 25 m² of water surface.

Note: 

Strongly recommended for pools in light colors. In pools with a dark or stainless steel finish, it is recommended 

to use more spotlights per m². 
• It is the responsibility of the fitter to ensure that the area around the connectors is completely watertight.
• The junction boxes should be placed at least 2 m from the edge of the pool or water facility.
• The 230/12 V transformer that feeds the LumiPlus Flexi should be installed at a distance of 3.5 m from the edge of 

pool or water facility.

• Cable ducts laid less than 3.5 m away from the edge of the pool must not be made of metal.
• The smallest cable cross-section that fits the LumiPlus Flexi is a 2 x 1 mm² H07RN-F.
• The largest cable cross-section that fits the LumiPlus Flexi is a 2 x 2 x 5 mm² H07RN-F.

 

ATTENTION

UNDER NO CIRCUMSTANCES SHOULD SCREWS OTHER THAN THOSE SUPPLIED BE USED FOR SCREWING THE 

LUMIPLUS FLEXI CABLE GLAND AS THEY COULD PIECE IT AND RESULT IN WATER GETTING INTO IT.

4. ASSEMBLY: 

LumiPlus FlexiSlim (See page 26)

LumiPlus FlexiNiche / FlexiRapid (See page 28)

Summary of Contents for LumiPlus V2 DMX

Page 1: ...NTO MANUALE DI INSTALAZIONE E MANUTENZIONE EINBAU UND BETRIEBSANLEITUNG MANUAL DE INSTRU ES E MANUTEN O LUMIPLUS FLEXI RGB DMX SPOTLIGHT POINT DE LUMI RE FLEXI RGB DMX PUNTO DE LUZ LUMIPLUS FLEXI RGB...

Page 2: ...T 2 SPECIFIC REQUIREMENTS SECTION 18 LIGHTS FOR SWIMMING POOLS AND SIMILAR APPLICATIONS The manufacturer is not responsible in any circumstances for assembly installation or start up of any electric c...

Page 3: ...must be made of the cross sections for each installation to ensure a 12 volt power supply reaches the LumiPlus Flexi and to prevent voltage drops LumiPlus Flexi has been designed to operate only with...

Page 4: ...IRING IN BUILDINGS SPECIAL WIRING SWIM MING POOLS All maintenance operations should be performed with the LumiPlus Flexi disconnected from the mains Do not handle with wet feet LumiPlus Flexi is desig...

Page 5: ...Il a une profondeur d immersion nominale de 2 m LumiPlus Flexi est conforme aux normes internationales de s curit des luminaires en particulier la norme EN 60598 2 18 LUMINAIRES 2 me PARTIE CONDITION...

Page 6: ...rigine il est n cessaire d effectuer un calcul sp cifique des sections pour chaque insta llation afin d alimenter LumiPlus Flexi avec un courant de 12 V et viter toute chute de tension Ce projecteur a...

Page 7: ...les normes IEC 364 7 702 INSTALLATIONS LECTRIQUES DANS L INT RIEUR DES B TIMENTS INSTALLATIONS SP CIALES PISCINES Il faut d brancher LumiPlus Flexi du r seau pour effectuer toute op ration d entretien...

Page 8: ...d de luminarias en especial la norma EN 60598 2 18 LUMINARIAS PARTE 2 REQUERIMIENTOS PARTICULARES SECCI N 18 LUMINARIAS PARA PISCINAS Y APLICACIONES SIMILARES El fabricante en ning n caso se responsab...

Page 9: ...lleguen al proyector LumiPlus y evitar excesivas ca das de tensi n ver p gina 24 Este proyector ha sido dise ado para funcionar nicamente con control DMX y con el modulador DMX de Astralpool No funcio...

Page 10: ...se con LumiPlus Flexi desconectado de la red No manipular con los pies mojados LumiPlus Flexi est dise ado PARA USAR NICAMENTE SUMERGIDO EN AGUA y est concebido PARA FUNCIO NAR NICAMENTE CON UN TRANSF...

Page 11: ...0598 2 18 ILLUMINAZIONE PARTE 2 PRESCRIZIONI PARTICOLARI SEZIONE 18 ILLUMINAZIONE PER PISCINE E APPLICA ZIONI SIMILARI II fabbricante rifiuta qualsiasi responsabilit per il montaggio I installazione o...

Page 12: ...are cos cadute di tensione Questo proiettore stato disegnato per per un funzionamen to esclusivo con controllo DMX e con i modulatore DMX di AstralPool Non funziona con alcun altro sistema di con trol...

Page 13: ...NI ELETTRICHE IN EDIFICI INSTALLA ZIONI SPECIALI PISCINE Qualsiasi operazione di mantutenzione o sostituzione di pezzi deve essere realizzata con il proiettore scollegato dalla rete No operare con i p...

Page 14: ...LumiPlus Flexi erf llt die internationalen Sicherheitsnormen f r Lampen vor allem die Norm EN 60598 2 18 LEU CHTEN TEIL 2 BESONDERE ANFORDERUNGEN SEKTION 18 LEUCHTEN F R SCHWIMMBECKEN UND HNLICHE ANW...

Page 15: ...LLS WIRD DIE PRODUKTGARANTIE UNG LTIG 6 CONNESSIONI ELETTRICHE LumiPlus Flexi wird mit einem Kabel 2x1mm2 H07RN F von 2 5 m geliefert Falls diese L nge nicht ausreicht kann das Kabel ersetzt werden si...

Page 16: ...ntage beauftragten Personen m ssen ber die f r diese Art Arbeiten erforderliche Qualifizierung verf gen Der Kontakt mit der Elektrospannung mu vermieden werden Die f r die Vermeidung von Unf llen g lt...

Page 17: ...seguran a de aparelhos de ilumina o em especial a norma EN 60598 2 18 APARELHOS DE ILUMINA O PARTE 2 REQUISITOS ESPECIAIS SEC O 18 APARELHOS DE ILUMI NA O PARA PISCINAS E APLICA ES SIMILARES O fabric...

Page 18: ...ue os 12 volts chegam a LumiPlus Flexi e evitar quedas de tens o Este projetor foi concebido para funcionar apenas com o con trolo DMX e com os modulador DMX da AstralPool N o funcio na com nenhum out...

Page 19: ...os p s molhados LumiPlus Flexi foi concebida exclusivamente PARA SER UTILIZADA MERGULHADA NA GUA e PARA FUNCIONAR COM UM TRANSFORMADOR DE SEGURAN A LumiPlus Flexi resiste aos tratamentos de piscina d...

Page 20: ...20 FIG 5 5mm x2 FIG 6 FIG 2 FIG 3 FIG 4 FIG 1 FlexiSlim x3 6 Nw...

Page 21: ...21 FIG 7...

Page 22: ...22 5mm FIG 1 FIG 3 FIG 2 FIG 4 FlexiRapid FlexiNiche x2 x3 6 Nw FIG 5 FIG 6...

Page 23: ...23 FIG 7...

Page 24: ...WW 71212 71214 71216 71203 71205 71206 71207 71204 71208 71644 Cable Flexi 2x2 5 mm of 5 mts 71201 71201WW 71213 71215 71217 71202 71202WW 71200 71200WW 71212 71214 71216 71203 71205 71206 71207 71204...

Page 25: ...n 2014 35 CEE Europ ische Norm EN 60598 1 EN 60598 2 18 mit allen nderungen D CLARATION CE DE CONFORMIT Les produits num r s ci dessus sont conformes La Directive de compatibilit lectromagn tique 2014...

Page 26: ...26...

Page 27: ...27...

Page 28: ...documento sem aviso pr vio Made in Spain Sacopa S A U Pol Ind Poliger Sud Sector I 17854 Sant Jaume de Llierca Spain ASTRALPOOL Avda Francesc Maci 60 planta 20 08208 Sabadell Barcelona Spain info astr...

Reviews: