Astralpool KIVU 56633 Original Instructions Manual Download Page 8

ENGLISH

9

KIVU PUMP

 - ASTRALPOOL

• Adjust the thermal value according to the thermal protection table. For the connection 

 (3 x 230 V network), use the protection 

with the highest indicated value. For the connection 

Υ

 (3 x 400 V network), use the protection with the lowest indicated value.

• Connect the lowest voltage at 

 and the highest at 

Υ

 for voltage intervals other than 230/400 V; 400/690 V.

• For AC, use a H07 RN-F3 type connection sleeve with a cable section that adapts to the power of the motor and the 

length of the cable.

• The mains cable may only be connected by skilled, authorised personnel.

VARIABLE FREQUENCY DRIVE

• These pumps are suitable for use with a variable frequency drive.
• It is recommended that you work within the limits of 20Hz to 50Hz.
• For more information, contact the supplier of the variable frequency drive.

8. START-UP INSTRUCTIONS 

PRIOR TO START-UP

-   Carry out the following operations before starting the pump:

1. Remove the pre-filter cap by unscrewing the nut holding it in place.
2. Fill the pump with water through the pre-filter until it rises up through the suction pipe.
3. Should the basket be removed during these operations, do not forget to replace it to prevent large particles from 

entering the pump that could block it.

4. Fit the pre-filter cap and screw on tight, not forgetting to fit the seal in its housing.
5. Check that the mains voltage and frequency correspond with those indicated on the pump characteristics plate.

-  The pumps must not be run without the pre-filter having first been filled with water. Where this is not the case, the 

mechanical gasket may be damaged, leading to a loss of water.

-  Check that the motor rotates in the correct direction by means of the fan located at the back of the motor that can be seen 

through the view hole on the fan cover.

START-UP

-  Open all the valves and connect the motor.
-   Activate the self-priming and wait a reasonable time for this to be completed.
-  The PUMP MUST NEVER FUNCTION WHEN IT IS DRY. The pump must not be started when it is dry as this would cause 

damage to its mechanical seal, causing water leaks. 

-  The pump cannot function against a closed valve as this will cause an increase in the temperature and formation of 

steam in the pump, which could cause it damage.

MINIMUM PRESSURE -NPSHr /CAVITATION

-  The minimum suction pressure depends on the flow rate and power of the Kivu pump. See NPSHr graphs.
-  If the pump does not have the minimum pressure required, it can cavitate. Steam would cause vibrations that would 

damage the moving parts of the pump (impeller, mechanical seal, bearings) and fixed parts (flange, diffuser, volute).

-  To avoid the effect of cavitation in the pump, ensure that the minimum pressure at the inlet of the pump is that required 

in the NPSHr graph.

Summary of Contents for KIVU 56633

Page 1: ...ES ISTRUZIONI ORIGINALI ORIGINALANLEITUNG INSTRU ES ORIGINAIS CENTRIFUGAL PUMP FOR SWIMMING POOLS POMPES CENTRIFUGE POUR PISCINES BOMBAS CENTR FUGAS PARA PISCINAS POMPE CENTRIFUGHE PER PISCINE ZENTRIF...

Page 2: ...ccessories authorised by the manufacturer ensure greater safety The pump manufacturer is exempt from all liability regarding any damage caused by unauthorised spare parts or accessories When working o...

Page 3: ...ine is running and or before it comes to a complete standstill Wait for the machine to come to a halt before handling it Before any electrical or mechanical maintenance operation disconnect the unit f...

Page 4: ...motor one on the cover of the terminal box and another on the fan cover LABEL ON THE COVER OF THE TERMINAL BOX It provides information on the hydraulic characteristics of the pump Fig 4 Ref Pump code...

Page 5: ...ing and receives dry ventilation 6 INSTALLATION AND ASSEMBLY Our pumps may only be assembled and installed in pools or ponds that are compliant with HD 384 7 702 Should you have any doubts please cons...

Page 6: ...ut off valves on both sides of the pump to prevent the system from emptying if we have to clean or repair the pump Check that the pipes are held in place as close as possible to the pump both on the s...

Page 7: ...itable mains connections involve the risk of electrocution For pumps with a three phase motor Use a motor guard with magneto thermal protection Protect the pump against overloads with a cut off switch...

Page 8: ...rew on tight not forgetting to fit the seal in its housing 5 Check that the mains voltage and frequency correspond with those indicated on the pump characteristics plate The pumps must not be run with...

Page 9: ...mmediately and contact the nearest Technical Assistance Service Should the pump stop check that consumption of the running motor in amperes is equal to or below that indicated on the manufacturer s ch...

Page 10: ...tor turning Invert 2 power phases Wrong voltage Check the voltage on the characteristics plate and that of the mains Pre filter blocked Clean the filter Load loss in the installation Prevent parts fro...