Astralpool KIVU 56633 Original Instructions Manual Download Page 10

ENGLISH

11

KIVU PUMP

 - ASTRALPOOL

11.  TROUBLESHOOTING

  1. The pump is not primed 

 

4. The pump will not start

  2. The pump releases only a small flow of water  5. The motor is making a noise but will not start
  3. The pump makes a noise 

 

6. The motor is stopped

1 2 3 4 5 6

CAUSES

SOLUTIONS

Air entering the suction pipe

Check the condition of connections and seals on the suction pipe

Filter cap badly sealed 

Clean the filter cap and check the condition of the rubber seal

Inverted motor turning 

Invert 2 power phases

Wrong voltage

Check the voltage on the characteristics plate and that of the 

mains

Pre-filter blocked 

Clean the filter

Load loss in the installation 

Prevent parts from causing load loss wherever possible

Pump incorrectly secured

Secure the pump correctly

Motor blocked 

Remove the motor and contact the technical service

Increased temperature in the terminal 

box due to electric arc

Check the terminal box connections

The thermal protection trips

Connect the cables correctly to the terminal boxes

Incorrect terminal box connections

Tighten the cable correctly to the terminal / Adapt the size of the 

cable connection to the terminal box

Summary of Contents for KIVU 56633

Page 1: ...ES ISTRUZIONI ORIGINALI ORIGINALANLEITUNG INSTRU ES ORIGINAIS CENTRIFUGAL PUMP FOR SWIMMING POOLS POMPES CENTRIFUGE POUR PISCINES BOMBAS CENTR FUGAS PARA PISCINAS POMPE CENTRIFUGHE PER PISCINE ZENTRIF...

Page 2: ...ccessories authorised by the manufacturer ensure greater safety The pump manufacturer is exempt from all liability regarding any damage caused by unauthorised spare parts or accessories When working o...

Page 3: ...ine is running and or before it comes to a complete standstill Wait for the machine to come to a halt before handling it Before any electrical or mechanical maintenance operation disconnect the unit f...

Page 4: ...motor one on the cover of the terminal box and another on the fan cover LABEL ON THE COVER OF THE TERMINAL BOX It provides information on the hydraulic characteristics of the pump Fig 4 Ref Pump code...

Page 5: ...ing and receives dry ventilation 6 INSTALLATION AND ASSEMBLY Our pumps may only be assembled and installed in pools or ponds that are compliant with HD 384 7 702 Should you have any doubts please cons...

Page 6: ...ut off valves on both sides of the pump to prevent the system from emptying if we have to clean or repair the pump Check that the pipes are held in place as close as possible to the pump both on the s...

Page 7: ...itable mains connections involve the risk of electrocution For pumps with a three phase motor Use a motor guard with magneto thermal protection Protect the pump against overloads with a cut off switch...

Page 8: ...rew on tight not forgetting to fit the seal in its housing 5 Check that the mains voltage and frequency correspond with those indicated on the pump characteristics plate The pumps must not be run with...

Page 9: ...mmediately and contact the nearest Technical Assistance Service Should the pump stop check that consumption of the running motor in amperes is equal to or below that indicated on the manufacturer s ch...

Page 10: ...tor turning Invert 2 power phases Wrong voltage Check the voltage on the characteristics plate and that of the mains Pre filter blocked Clean the filter Load loss in the installation Prevent parts fro...

Reviews: