ENGLISH
11
KIVU PUMP
- ASTRALPOOL
11. TROUBLESHOOTING
1. The pump is not primed
4. The pump will not start
2. The pump releases only a small flow of water 5. The motor is making a noise but will not start
3. The pump makes a noise
6. The motor is stopped
1 2 3 4 5 6
CAUSES
SOLUTIONS
Air entering the suction pipe
Check the condition of connections and seals on the suction pipe
Filter cap badly sealed
Clean the filter cap and check the condition of the rubber seal
Inverted motor turning
Invert 2 power phases
Wrong voltage
Check the voltage on the characteristics plate and that of the
mains
Pre-filter blocked
Clean the filter
Load loss in the installation
Prevent parts from causing load loss wherever possible
Pump incorrectly secured
Secure the pump correctly
Motor blocked
Remove the motor and contact the technical service
Increased temperature in the terminal
box due to electric arc
Check the terminal box connections
The thermal protection trips
Connect the cables correctly to the terminal boxes
Incorrect terminal box connections
Tighten the cable correctly to the terminal / Adapt the size of the
cable connection to the terminal box