-12-
CHLORINE ANALYSIS METHOD
The analysis should be made at approximately the same time and the same place (at
a point equidistant between the backflow and the skimmer). The chlorine produced by
your salt chlorinator is very volatile and the reading of its content may vary according
to different parameters (UV, number of bathers, organic matter, etc.). If there is an
exceptionally high number of bathers, then we advise you to switch the filtration to
manual mode in order to compensate for the chlorine deficit caused by this excessive
number of bathers.
INDOOR POOLS OR POOLS WITH COVERS
If swimming-pool water is not exposed to UV rays, then the chlorine content may
become excessive and therefore corrosive.
Shelter/cover: we advise that you adjust the production of your salt chlorinator when
the shelter or cover is open. The factory setting is 50% ; in order to change this pro-
ceed as follows :
Switch off the device
-
Press + and - simultaneously while switching on the device.
- Keep + and - pressed until the screen displays ATT then PRO
Press + and FE appears.
- Press Menu to Confirm.
- The screen displays a production-time setting for a closed cover.
- Press + or - to change the production setting when the cover is closed.
- Press Menu to Confirm.
ADJUSTING THE DURATION OF THE POLARITY INVERSION
Your salt chlorinator was programmed in the factory for a polarity change every three
hours.
According to the hardness of the water (TH for degree of Total Hardness), it is possi-
ble to change this cycle from one to six hours.
Switch off the device
-
Press + and - simultaneously while switching on the device.
- Keep + and - pressed until the screen displays ATT then PRO.
- Press Menu : DUR appears.
- Press Menu : the duration of the polarity inversion is displayed; press + or - to
change the value.
- Press Menu to Confirm.
SELF-TEST :
Attention! Water temperature > 23°C, minimum salt content 4 g/l.
This function allows one to check the state of the electrode and that the unit is work-
ing properly.
Press the “TEST” key.
The LEDs light up,
Then “prod1” followed by “prod2”.
If all of the LEDs flicker after 30 second, then the test is OK.