-11-
Menu
Prod1
Cover
Prod2
Stand-by
Production fault
Self-test
Flow-rate detector fault
RECOMMENDATIONS
Please respect the following values in order to ensure the proper operation of this
electrolyser :
Salt content :
Recommended :
4 g/l
Minimum :
3,2 g/l
pH :
Recommended :
less than 7,6
Stabilizer :
Recommended :
10 à 15 g/m
3
Maximum :
40 g/m
3
Minimum daily operating
time :
respect the recommendations of the
manufacturer of your filtration system.
Water temperature :
do not use below 15°C.
Connection :
220 volts - 50/60 Hz must be connected
to the filtration pump.
START-UP OF THE SALT CHLORINATOR
Ensure that the salt content is correct.
Place the switch to “on”: the fan will start, the "stand-by" indicator will light up,
followed by Prod1 and finally the ampere display. The electrode will turn on automati-
cally after a period of time.
ADJUSTING CHLORINE PRODUCTION
Starting-up for the first time :
a) Press the + key to 100%, letting the filtration run 24h/24 until the required
chlorine content is reached (minimum 0.5 ppm).
b) Switch the filtration to automatic and check the chlorine content regularly.
c) Adjust production by using the + or - keys if the desired rate is too low or
two high.
d) Add chlorine products manually if it takes more than 48 hours to fill the
pool.
POLARITY 1
POLARITY 2