0
S I G N A T U R E
Check that the motor rotates in the correct direction by means of the fan located at the
back of the motor that can be seen through the view hole on the fan cover (Fig. 6).
Check that the pump shaft turns freely.
7.7.2. START-UP
Open all the valves and connect the motor.
Activate the self-priming and wait a reasonable time for this to be completed.
7.7.3. WARNINGS DURING START-UP
Before starting the machine, check the calibration of the electric protection devices on the motor
and that the protection against electrical and mechanical contacts is correctly positioned and
secure.
NOTE
The pool should not be used while the pumping equipment is running.
Do not use the pump if anyone is in contact with the water.
8. Maintenance and disassembly
8.1. MAINTENANCE
Clean the pre-filter basket regularly to avoid drops in pressure. To prevent the basket
from breaking, do not hit it during the cleaning process.
Should the pump stop, check that consumption of the running motor in amperes is equal
to or below that indicated on the manufacturer’s characteristics plate. If this information
is available, contact the nearest Technical Assistance Service.
Where the amperage is higher, consult the manufacturer.
Empty the pump if it is to remain at a standstill for a certain length of time, especially in
cold countries where there is a risk of freezing.
Remove the purge cap (0) to empty the pump.
Every time the pre-filter is opened, clean the seal and its seating of any impurities to
ensure airtightness when the cap is closed (Fig. 5).
Pump components that, due to their normal use, suffer wear and/or tear must be regu-
larly replaced to ensure good pump performance. The following table shows the perisha-
bles and/or consumables used in the pump and their estimated working life.
•
•
•
•
•
•
•
•
•
•
•