Inspect the following parts annually. Replace as needed:
f) Inlet Water Electrovalve (A10360 for 110V or A10361 for 220V machines)
g) Steam Pivot Rebuild Kit -Spring, Brass Seat, & 2 O-Rings (A10469)
h) Steam Valve Kit, No Wand- (A10440) or Complete Kit w/ Steam Wand- (A10441)
*Parts can be ordered on www.astramfr.com
3
. Check the pressure-stat:
a) Open the steam wand and at the same time look at the amber light and the gauge
b) The amber light must be lit when the pressure drops to 12 - 13 PSI
c) If it does not the pressure-stat must be replaced (A10170)
4
. Make sure that the vacuum valve on top of the boiler is not stuck in the up position. If it
is, it must be replaced.
5
.Turn the machine OFF, UNPLUG the machine and make sure that ALL of the electrical
connections are tight and secure and that there are no signs of burn damage to the
electrical connections or plugs.