USER manual
32
of
160
2.5
Data and CE marking
The technical data of the machine is shown in the
following table:
TECHNICAL DATA TABLE
JUN
1GR
COMPACT
2GR
3GR
4GR
Voltage (V)
120
230-400
240
120
230-400
240
120
230-400
240
120
230-400
240
230-400
240
230-400
240
Frequency (Hz)
50/60
50/60
50/60
50/60
50/60
50/60
Max power (kW)
2.4 kW
2.4/3.1/3.3
3.1
3.1/3.9/4.2
5.6/6.0
6.6/7.1
Boiler (l)
5
6/8
7
10.5/14
17/21
23
Safety valve
calibration (bar)
1.9 bar
Boiler operating
pressure
0.8 - 1.4 bar
Feed water pressure
1,5 - 5 bar MAX
Coffee dispensing
pressure
8 - 9 bar
Operation mode
temperature
5 - 40°C 95° MAX R.U.
Sound pressure level
< 70 dB
According to the Directive 2006/42/EC, the machine is
marked with the CE marking, by which the manufacturer
declares, under its own responsibility, that the machine
is safe for people and things.
The CE nameplate is affixed to the base of the frame
under the drain pan on which the identification data is
reported. Below is an example of the nameplate:
Via C. Bardini,1 SUSEGANA (TV) - ITALY
Tel. +39.0438.6615 Fax +39.0438.60657
MADE IN ITALY
W
S/N:
Mod.
Hz
Y
V
CMA MACCHINE PER CAFFÈ S.r.l.
MARCHIO COMMERCIALE
For any communication with the Manufacturer, al-
ways note the following information:
t
S/N - machine serial number;
t
Mod. - machine model
t
Y - year of manufacture;
The data of the appliance can be seen also on the
label located on the package of the machine.
It is forbidden to remove or damage the nameplate. If it needs
replacing urgently, always exclusively contact the Manufacturer.
The CE tag is affixed on the
base of the frame under the
drain pan
3.
STORAGE
The machine is stored by the Manufacturer or the
Distributor.
4.
INSTALLATION
The installation of the machine must be performed
only by the Manufacturer's Qualified Technicians.
During the installation the Qualified Technicians needs to renewal
operations of the water contained in the hydraulic circuits.
The base of the machine support must be perfectly level and
without irregularities.
The electric system must be equipped with a suitable differential
circuit breaker (30 mA).