5.2 Digital output
The digital output circuitry consists of an opto-isolated, solid-state relay for switching power
to external loads.
Each digital output circuit has a continuous current rating of 120 mA maximum and a max-
imum power dissipation rating of 180 mW. While providing 10 mA of load current, the
MOSFET on-state resistance is typically 21. The relay's maximum response frequency is 500
Hz.
Type
Opto-isolated
Maximum continuous current rating
120 mA
Maximum power dissipation
180 mW
Maximum frequency response
500 Hz
5.2.1 Surge protection for digital output circuitry
When driving an inductive load (e.g., a relay coil), always use a C/R snubber or clamping
diode in parallel with the load to suppress large spikes.
14
Copyright © 2022 Advanced Simulation Technology inc.
ACE-RIU Technical User Guide (Rev. K, Ver. 4)
Summary of Contents for ACE-RIU
Page 2: ......