Parameterization
VLM60 User Manual
ASTECH GmbH
page 19
SO2Time
Used to set the time interval for regular output to the internal communication interface S2.
so2t
ime [n]
n = 1 ... 65535 (unit: ms)
default: 30
If the time interval is set smaller than the
Average
parameter, it must be noted that there is no updated speed
value because the time of
Average
has not yet expired.
Tilt
Serves to set angle specifications corresponding to the inclination/rotation of the mounting position of the
VLM60. For better reflection of the surface contrasts, a correction of the mounting position may be necessary.
This angle correction only applies to flat measuring surfaces!
tilt
[f1] [f2]
f1 = 1.000 ... 45.000 f2= 1.000 … 45.000 (
unit: degree)
default: 0.000 0.000
f1
corresponds to the angle of inclination in the x-direction, i.e. the roll angle beta.
f2
corresponds to the angle
of inclination in the y-direction, i.e. the pitch angle gamma. For the angle designation, compare Figure 2.
Trigger
Used to configure the switching input (TRIGGER) for internal length measurement.
trig
ger [n]
n = 0 …3
default: 0
n
Event
Usage
0
H-Level
single part measurement
1
L-Level
single part measurement
2
L/H-Transition
continuous measurement
3
H/L-Transition
continuous measurement
Single part measurement: If the signal goes to the active level, the length measurement is started and stopped
at the next level change.
Continuous measurement: A continuous measurement is performed. A trigger edge stops the measurement
and simultaneously triggers the next measurement.
Simultaneously with a stop of the length measurement, the affected output channel is updated in case of
trigger-synchronous output (see PO1Sync, PO2Sync, SO1Sync and SO2Sync commands).