Manual Load Switch LS 804
Page 4 of 34
Subject to technical changes. 06/2017
A.S.T. - Angewandte System Technik GmbH, Mess- und Regeltechnik
4.3.
Sensor inputs I a – I d
A total of four sensor connections are available.
Conductors of up to 1.0 mm
2
can be connected up to terminal blocks 31 to 50.
4.3.1.
LS 804.01
The LS 804.01 is designed for DMS sensors with a signal output range extending from -5mV/V to
+5mV/V. The bridge resistors may be from 350 Ω ... 1000 Ω.
Input stages "I 1a" and "I 1b" serve to feed the DMS sensors with 5 V, input stages "I c" und "I d"
supplying the DMS sensors with 3.3V.
50 49 48 47 46
45 44 43 42 41
40 39 38 37 36
35 34 33 32 31
Signal a
Signal c
Signal b
Signal d
a
c
b
d
-S
I c
-SI
a
+
S
I c
+
SI
a
+
EX
c
+E
X a
-EX
c
-EX
a
S
H
I c
SHI
a
+
EX
d
+
EX
b
+S
I d
+S
I b
-S
I d
-S
I b
-EX
d
-EX
b
SH
I d
SH
I b
CAN
RS 485
F3
F2
F1
Figure 4– Sensor inputs I a – I d (LS 804.01)