5.3.2.
Operating display / network for browser accessing
Information on the network addresses and other details can be obtained from the operating display of the
sensor signals by pressing keys
and
simultaneously.
L S 8 0 4 - I n f o r m a t i o n
I P S c a l e E x i t
Figure 16 - LS804 – Information
Actuating key
IP
serves to display network information including the IP address of the device, by
means of which it is possible to access to the LS 804 via a browser.
N e t w o r k : D H C P O N
I P : 1 9 2 . 1 6 8 . 1 0 0 . 2 0
N M : 2 5 5 . 2 5 5 . 2 5 5 . 0
G W : 1 9 2 . 1 6 8 . 1 0 0 . 1
Figure 17 – Network information
D e f a u l t - I P : 1 9 2 . 1 6 8 . 1 . 1 0
D H C P d e f a u l t O N
The IP address can be assigned automatically from a linked-up DHCP server if the value "DHCP = On"
has been set (also refer to Chapter 6.2. Settings (scaling, interfaces, password)).
If no DCHP server is found in the network, the IP address will have been set to the above value.
Default login data (if default): Login:
admin) /
Password:
admin
(refer to Chapter 6.2).
Pressing the
key returns the user to menu "LS804 – Information".
Key
Scale
indicates the 100% values (nominal characteristics) of sensors a to d (also refer to
Chapter 6.2 Settings (scaling, interfaces, password)).
Actuating
or
brings about a display change of sensors a/b and c/d.
In addition the LS 804 variant (mV / mA) will be displayed as well as the current limit set.
M e a s . s c a l e s e t t i n g s
V a r : m V / L s : 2
a: 1 0 0 . 0 t
b:
2 0 . 0 t
Figure 18 – Scaled values for signal a and signal b
Actuating the
button returns the user to menu " LS804 – Information".