G
ETTING
S
TARTED
3
Rotor
—
Stator Assembly Instructions
Unwrap rotor and connecting
driveshaft.
Release locking cam ears on
the pump housing base.
Slide out the stator tube & pump
housing retainer assembly.
Thoroughly lubricate the inside of the
stator tube with liquid dish soap.
Apply a liberal amount of liquid dish
soap to the outside of the rotor.
Screw and push the rotor into the
stator tube, counter-clockwise.
Slide the rotor-stator assembly into the
pump housing base. If the assembly
does not go all the way back, check the
connecting drive shaft alignment.
The rotor should stick out approx. 2”
as shown above, making sure the
gasket in the brass retainer stays in
place.
The connecting drive shaft must
align with the square receiver on
the rigid coupling.
If the rotor is inserted far enough and the connecting drive shaft is
aligned, the assembly will connect back into it’s original position and
can be locked back in place. The Rotor-Stator Assembly is complete.
Reinstall the hopper.
If it will be more than a week between use, it is best to disassemble
these parts and reassemble when needed.
Uncrate the Kodiak and inspect all parts for any shipping damage.
Remove the rotor and connecting driveshaft from the hopper and follow the Rotor-Stator Assembly Instructions below: