20.

 

GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS

 

The charger should be grounded to reduce the risk of electric shock.  This charger is equipped with an electric cord having an equipment 
grounding conductor and a grounding plug.  The plug must be plugged into an outlet that is properly installed and grounded in accordance with 
all local codes and ordinances. 

DANGER.

  Never alter the AC cord or plug provided - if it will 

not fit the outlet, have a proper outlet installed by a qualified 
electrician.  Improper connection can result in a risk of an 
electric shock.  This battery charger is for use on a nominal 
120-volt circuit, and has a grounding plug that looks like the 
plug illustrated in FIGURE (A).  A temporary adapter, which 
looks like the adapter illustrated in FIGURE (C), may be used 
to connect this plug to a two-pole receptacle, as shown in FIGURE (B), until a properly grounded outlet can be installed by a qualified 

GROUNDED

OUTLET

GROUNDING METHODS

GROUNDING

MEANS

ADAPTER

COVER OF GROUNDED

OUTLET BOX

(A)

(B)

(C

ADAPTER

)

electrician. 

DANGER.

  Before using an adapter as illustrated, be certain that the center screw of the outlet plate is grounded.  The green-colored rigid 

ear or lug extending from the adapter must be connected to a properly grounded outlet - make certain it is grounded.  If necessary, re
original outlet cover plate screw with a longer screw that will secure the adapter ear or lug to the outlet cover plate and make groun
connection to grounded outlet.  NOTE: 

USE OF AN ADAPTER IS NOT ALLOWED IN CANADA.  IF A GROUNDING TYPE 

RECEPTACLE IS

place the 

 NOT AVAILABLE, DO NOT USE THIS APPLIANCE UNTIL THE PROPER OUTLET IS INSTALLED BY A QUALIFIED 

21.

 

 For instructions for NEGATIVE clamp attachment 

refer to section 18f or 18g. 

 

22.

 

e of battery and state of charge per charts 

d.

 

uld be 

approximately 125

°

F.  Do not overcharge batteries.  Overcharging results in excessive water loss and eventual damage to the battery. 

 

 

ELECTRICIAN. 

NOTE: SIDE TERMINAL TO BE USED IN POSITIVE CLAMP ONLY!

 

 

 

 

Storage position 
Will not get lost.  Always ready to use. 

ed, 

holds adapter firm.  Will not slip back. 

 spring 

nsion holds adapter firm. 

 

 battery is determined to be defective. 

Extended position 
Note: Pressure, when handle is squeez

Thrust on terminal 
Note: Clamp is released and
te

 

LENGTH OF CHARGE

 

a.

 

Test the battery for state of charge.  Do not charge if it is over 75% charged or the

b.

 

Set beginning amps charge rate for siz

c.

 

Charge for length of time per charge, 
Discontinue charge when the specific gravity of electrolyte reaches 1.260 or above.  A temperature compensating hydrometer sho
used for this reading.  Discontinue charge if the battery begins to gas excessively or if the temperature of the electrolyte reaches 

23.6

11.8

5.9

1.110

23.8

11.9

5.95

1.140

24.2

12.1

6.05

1.185

24.8

12.4

6.2

1.225

25%

50%

75%

DEAD

Open Circuit Voltage-24 V.

Open Circuit Voltage-12 V.

Open Circuit Voltage-6 V.

Specific Gravity

STATE OF CHARGE

STATE OF CHARGE TABLE

Cold Cranking Amps

Reserve Capacity

Ampere Hours

BATTERY SIZE

60

90

350

80+

100+

400+

40

60

275

BATTERY SIZE TABLE

LARGE

MEDIUM

SMALL

BATTERY SIZE %CHARGE

0-25

30

30

30

45

45

50

20

20

20

30

35

40

5

5

20

25

15

25

20

35

55

15

25

45

10

20

30

20

40

55

15

30

50

10

20

30

30

60

90

25

45

70

15

30

45

15

15 15 15

10

10

10 10 10

15 30 45 60 75 90

A

M

P
E
R
E
S

SMALL

MEDIUM

LARGE

 CHARGE RATE Vs. MINUTES CHARGE

25-50

50-75

50-75

25-50

0-25

50-75

25-50

0-25

MINUTES

 

Summary of Contents for Heavy Duty Comercial Charger 6001 A

Page 1: ...d when you work near a lead acid battery b Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes c Wear complete eye protection and clothing protection Avoid touching eyes while working near battery d If battery acid contacts skin or clothing wash immediately with soap and water If acid enter eyes immediately flood eyes with running cold water for at least ...

Page 2: ...contact button of the STOP GO LITE to the NEGATIVE NEG N battery post Interpret the light and take appropriate action When the green light is on connect the NEGATIVE BLACK clamp to the vehicle chassis heavy gauge metal part of the frame or engine block away from the battery Do not connect to the carburetor fuel lines or sheet metal body parts g For positive grounded vehicles connect the POSITIVE R...

Page 3: ...S APPLIANCE UNTIL THE PROPER OUTLET IS INSTALLED BY A QUALIFIED 21 For instructions for NEGATIVE clamp attachment refer to section 18f or 18g 22 e of battery and state of charge per charts d uld be approximately 125 F Do not overcharge batteries Overcharging results in excessive water loss and eventual damage to the battery ELECTRICIAN NOTE SIDE TERMINAL TO BE USED IN POSITIVE CLAMP ONLY Storage p...

Page 4: ...the charger connected to the battery Follow the duty cycle on the unit Turn the switch to OFF and remove the AC power cord from the electric outlet before disconnecting the DC clamps DIESEL VEHICLES Diesel engines have special starting requirements due to the high compression required to ignite the fuel mixture Because of this the starter motors have to work harder which requires the battery to de...

Page 5: ...tart of the charging process This will continue until the sulfation begins to break down CAUTION AS THE SULFATION BREAKS DOWN THE AMPERAGE MAY RAPIDLY RISE CONSTANT ATTENTION MUST BE OBSERVED TO PREVENT SERIOUS OVERHEATING OF THE BATTERY 4 Lower the charge rate to the lowest rate for the voltage of battery being charged 5 Charge the battery at this low rate until the electrolyte reaches the fully ...

Page 6: ...s indiqués sur ces produits et sur le moteur 13 PRÉCAUTIONS PERSONNELLES a S assurer que quelqu un est à portée de voix ou suffisamment près pour prêter assistance lorsqu on travaille près d une batterie au plomb b Avoir à la portée de la main une réserve suffisante d eau fraîche et du savon au cas où l acide de la batterie entrerait en contact avec la peau les vêtements ou les yeux c Porter des l...

Page 7: ...borne négative NEG N d Déterminer quelle borne est mise à la masse reliée au châssis Si la borne négative est mise à la masse au châssis comme dans la plupart des véhicules voir l article e Si la borne positive est mise à la masse au châssis voir l article f e Pour un véhicule avec masse au négatif brancher la pince positive ROUGE du chargeur à la borne positive POS P non mise à la masse de la bat...

Page 8: ...TILISER CET APPAREIL 21 NOTE BORNES SUR LE COTE NE DOIVENT ETRE QUE SUR LES SERRE JOINTS POSITIFS Pour les instructions pour les serre joints negatifs voir sections 18e ou 18f Position en accumulation Prolonger la position Pouser les bornes Ne se perdera pas Toujours pret a servir Note pression quand la poignee est compressee tient l adaptateur fermement Ne pas glisser en arriere Note Les serre jo...

Page 9: ...aire pour allumer le melange de fuel A cause de ceci le starter du motor a besoin de travailler plus ce qui oblige la batterie a donner une plus grande puissance pendant un certain temps Un voltage adequate doit etre fourni pour que la prise incandescente est assez d energie pour pre chauffer la chambre Quand on essaye de faire demarrer un vehicule diesel toujours charger la batterie rapidement pe...

Page 10: ...batterie a ce faible taux jusqu a ce que l electrolyte soit completement charge comme decrit dans les tableau du manual d intruction Cela peut pendre de 2 a 3 jours NOTE QUELQUES BATTERIES SONT TELLEMENT SULFATEES QU ELLES NE PEUVENT ETRE REMISES EN CONDITION D OPERATION INDIFFERENT DU TAUX DE CHARGE OU DE LA DUREE DE CHARGE SI LA BATTERIE NE PEUT ETRE COMPLETEMENT RECHARGER PAR CHARGEMENT LENT EL...

Page 11: ...S a Al trabajar con baterías de ácido de plomo ha de tener a alguien que pueda acudir en su ayuda en caso necesario b Tenga suficiente agua fresca cerca por si el ácido llegase a su piel ropa u ojos c Lleve protección en los ojos y en la ropa Evite tocarse los ojos cuando trabaje cerca de la batería d Si el ácido llegase a su piel o a su ropa lávese inmediatamente con agua y jabón Si el ácido lleg...

Page 12: ...va conecte la pinza positiva roja del cargador de baterías a la terminal no a tierra Positiva Pos P de la batería Conecte el botón de contacto Stop Go a la terminal Negativa de la batería Interprete la luz y realice lo conveniente Cuando la luz verde se enciende conecte la pinza negativa negra al chasis del vehículo o parte pesada de metal No conecte la pinza al carburador o a los tubos de combust...

Page 13: ...de la pinza negativa refierase a la sección 18f o 18g Posición de almacenaje Posición extendida Conexión a la terminal No se perderán Siempre listas para ser usadas Nota la presión cuando aprieta la pinza sujeta el adaptador No se soltará Nota la tensión en la pinza y el muelle sujetan el adaptador 22 DURACIÓN DE LA CARGA a Mida la batería para ver el estado de carga No cargue si está cargada más ...

Page 14: ...peraje de arranque más bajo Ponga el interruptor en la posición de arranque START Encienda el coche con el cargador conectado a la batería NOTA no encienda el motor más de 20 segundos en periodos de 5 minutos Mientras espera que el starter se enfríe deje que el cargador siga cargando la batería Ponga el cronómetro en OFF antes de desconectar las pinzas VEHÍCULOS DIESEL Los motores diesel tienen un...

Page 15: ...O MIENTRAS EL SULFATO SE DESCOMPONE LOS AMPERIOS PUEDEN AUMENTAR RÁPIDAMENTE SE NECESITA ATENCIÓN CONSTANTE PARA PREVENIR EL SOBRECALIENTAMIENTO DE LA BATERÍA 4 Baje la medida de carga a la medida más baja para los voltios de la batería que está cargando 5 Cargue la batería a la medida más baja hasta que el electrolito llegue al estado de carga completa como está explicado en las tablas de su manu...

Page 16: ...lice Del Ventilador 610189 8 Moteur de Ventilateur 610190 8 Motor Del Ventilador 610190 9 Disjoncteur C A 610464 9 Circuito Protector AC 610464 10 Minuterie 611245 10 Cronómetro 611245 11 Interrupteur Avec Bouton 1 611187 11 Interruptor 1 611187 12 Bouton 1 603147 12 Pomo 1 603147 13 Indicateur de Courant Charge 605204 13 Medidor del Amperaje Carga 605204 14 Cordon d alimentation C A 611253 14 Cab...