background image

3

DANGER.

 

 Before using an adapter as illustrated, be

certain that the center screw of the outlet plate is grounded. 
The green-colored rigid ear or lug extending from the adapter
must be connected to a properly grounded outlet - make
certain it is grounded.  If necessary, replace the original outlet
cover plate screw with a longer screw that will secure the
adapter ear or lug  to the outlet cover plate and make ground
connection to grounded outlet.

NOTE: USE OF AN ADAPTER IS NOT ALLOWED IN CANADA.  IF A GROUNDING TYPE RECEPTACLE IS NOT AVAILABLE, DO NOT
USE THIS APPLIANCE UNTIL THE PROPER OUTLET IS INSTALLED BY A QUALIFIED ELECTRICIAN.

21.

CHARGE PERIOD

The approximate required time to bring a battery to full charge state depends upon the number of ampere-hours (AH) depleted from the
battery.  AH's are determined by multiplying the number of hours times the number of amps supplied by a battery to a load and normally
indicated on the battery.  For example, if a load was connected to a battery, which drew 7 amps for a period of 5 hours, the battery will
have supplied 35 AH.  The approximate recharge time would then be calculated by dividing the 35 AH depleted from the battery, by the
charge rate of the charger.  To allow for tapering of the charge rate add 25 percent to the charge time.

OPERATING INSTRUCTIONS

This battery charger is designed to charge 12 volt batteries of either conventional or maintenance-free construction.  Rated output current
is 1.5 DC amps.  When operating this charger, carefully follow the instructions in sections 17 and 18.

POSSIBLE CHARGING PROBLEMS

This battery charger has been equipped with an automatic reset circuit breaker.  This protects the charger from temporary overload
conditions.  A severely discharged battery, a battery with shorted cells, or reversed charger connections at the battery will cause this
protective device to operate.  Under these overload conditions, the circuit breaker will open, and when cooled down will reset
automatically.  This cycling process can be identified by a clicking sound made during the opening and closing of the circuit breaker.

a.

Check for reverse polarity connections.

b.

The battery may have one or more shorted cells.  Cycling will start immediately and continue indefinitely.  If cycling has not stopped, 
disconnect the charger (AC power cord first) and have the battery tested.

MAINTENANCE INSTRUCTIONS

This charger requires minimal maintenance.  As with any appliance or tool, a few common sense rules will prolong the life of the battery
charger.  ALWAYS BE SURE THE CHARGER IS UNPLUGGED BEFORE PERFORMING ANY MAINTENANCE OR CLEANING.
1.

Store in a clean, dry place

2.

Coil up the cords when not in use. 

3.

Clean the case and cords with a slightly damp cloth.

4.

Clean any corrosion from the clamps with a solution of water and baking soda.

5.

Examine the cords periodically for cracking or other damage and have them replaced if necessary.

6.

WARNING:

 All other service should be done by qualified personnel only.

Summary of Contents for 9305

Page 1: ...ny equipment you intend to use in vicinity of the battery Review cautionary markings on these products and on the engine 13 PERSONAL PRECAUTIONS a Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery b Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes c Wear complete eye protection and c...

Page 2: ...LLOW THESE STEPS WHEN THE BATTERY IS OUTSIDE THE VEHICLE A SPARK NEAR THE BATTERY MAY CAUSE BATTERY EXPLOSION TO REDUCE THE RISK OF A SPARK NEAR THE BATTERY a Check the polarity of the battery post The POSITIVE POS P usually has a larger diameter than the NEGATIVE NEG N post b Attach at least a 24 inch long 6 gauge AWG insulated battery cable to the NEGATIVE NEG N battery post c Connect the POSITI...

Page 3: ...nventional or maintenance free construction Rated output current is 1 5 DC amps When operating this charger carefully follow the instructions in sections 17 and 18 POSSIBLE CHARGING PROBLEMS This battery charger has been equipped with an automatic reset circuit breaker This protects the charger from temporary overload conditions A severely discharged battery a battery with shorted cells or reverse...

Page 4: ...4 NOTES ...

Page 5: ...au plomb b Avoir à la portée de la main une réserve suffisante d eau fraîche et du savon au cas où l acide de la batterie entrerait en contact avec la peau les vêtements ou les yeux c Porter des lunettes de sécurité et des vêtements de protection Éviter de se toucher les yeux lorsqu on travaille à proximité d une batterie d Si la peau ou les vêtements entrent en contact avec l acide de la batterie...

Page 6: ...égative NEG N b Relier à la borne négative NEG N de la batterie un câble pour batterie isolé de calibre 6 AWG d au moins 24 pouces de long c Brancher la pince positive ROUGE du chargeur à la borne positive POS P de la batterie d Se tenir à distance de la batterie et dégager l extrémité du câble puis brancher la pince négative NOIRE du chargeur à l extrémité du câble e Ne pas faire face à la batter...

Page 7: ...LA CHARGE Ce chargeur de batterie a ete equipe d une mise automatique d un coupe circuit Cela protege la surcharge temporaire du circuit Une batterie bien dechargee une batterie avec des courts circuits ou des connections du chargeur branchees a l invers metteront le protecteur en route Pendant la surcharge le coupe circuit s ouvrira et quand le circuit se sera refroidit il se remettra automatique...

Page 8: ...8 NOTES ...

Page 9: ...a los ojos y ropa Evite frotarse los ojos mientras trabaja cerca de la batería de ácido de plomo d Si el ácido de la batería contacta su piel o ropa lávese inmediatamente con agua y jabón Si el ácido contacta sus ojos lávelos inmediatamente con agua corriente fresca durante al menos 10 minutos y obtenga atención médica e NUNCA fume o produzca chispas o llamas cerca de la batería o del motor f Sea ...

Page 10: ...cargador a la terminal libre del cable e No esté de cara a la batería cuando efectúe la conexión final f Cuando desconecte el cargador hágalo siempre de forma inversa al procedimiento de conexión y quite la primera conexión estando lo más lejos posible de la batería g Una batería marina barco debe ser quitada y cargada en la costa Para cargarla a bordo se requiere un equipo diseñado especialmente ...

Page 11: ...erre a Compruebe si las conexiones de polaridad son correctas b La batería podría tener una o más celdas vacías Si esto ocurre la aguja empezará a moverse y continuará haciéndolo indefinidamente Si no ha parado de moverse desconecte el cargador la toma de corriente AC primero y chequee la batería INSTRUCCIONES DE MANTENIMIENTO Este cargador requiere un mantenimiento mínimo Como con cualquier otro ...

Page 12: ...ory Associated Equipment Corporation makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages THIS IS THE ONLY EXPRESS LIMITED WARRANTY AND ASSOCIATED EQUIPMENT CORPORATION NEITHER ASSUMES NOR AUTHORIZES ANYONE TO ASSUME OR MAKE ANY OBLIGATION TOWARD THE PRODUCT OTHER THAN THIS EXPRESS LIMITED WARRANTY ASSOCIATE...

Page 13: ...13 FIG FILENAME DESCRIPTION 1 LOGO EPS ASSOCIATED LOGO 2 ATEC TIF ATEC LOGO 3 PLUG ENG PLT GROUNDING ADAPTER ENGLISH 4 PLUG FRA PLT GROUNDING ADAPTER FRENCH 5 PLUG ESP PLT GROUNDING ADAPTER SPANISH ...

Reviews: