background image

 

500-23710_1 

 

 

 

 
Package Contents 

 

 

Microwave 

motion sensor

 

 

Faceplate

 

 

Weather-resistant 

gasket 

 

Faceplate screws

 

 

Mounting ring

 

 

Instructions 

 

Adapter ring 

 

 

 

 

Specifications

 

ELECTRICAL

 

INPUT   12 to 24 VAC ±10%

 

12 to 24 VDC +30%/-10%

 

 

50 to 60 Hz

 

<1.5W

 

OUTPUT

 

Relay contact rating (max voltage) 

Relay contact rating (max current) 

Max switching power

 

Relay with switch-over contact (voltage free)

 

60 VDC/125 VAC

 

1A (resistive)

 

30W DC / 60 VAC

 

DETECTION RANGE

 

4” to 24” (10cm to 60cm)(adjustable) 

DETECTION MODE

 

Motion (bidirectional)

 

OUTPUT HOLD TIME

 

0.5-30 seconds 

 

OPERATING TEMPERATURE

 

-4 °F to +131 °F (-20 °C to +55 °C)

 

IMMUNITY

 

Immune to electrical and radio frequency interference

 

WEIGHT

 

0.34 lbs (0.15 kg)

 

REGULATORY

 

Electromagnetic compatibility (EMC) according to 

2004/108/EC FCC: G9B-21016 IC: 4680A-21016

 

Precautions 

1.  SHUT OFF power to header before attempting any wiring procedures. 
2.  MAINTAIN a clean and safe environment when working in public areas. 
3.  Constantly BE AWARE of pedestrian traffic around the door area. 

4. 

Always

 STOP pedestrian traffic through the doorway when performing tests that may 

result in unexpected reactions by the door. 

5. 

OBSERVE

 proper protocols for circuit board handling to protect the unit from 

electrostatic discharge. 

 

6. 

Before handling any board, ENSURE dissipation of any bodily charge.

 

7. 

CHECK placement of all wiring before powering to ensure that moving door parts do 

not catch wires and cause damage to equipment.

 

8. 

ENSURE compliance with all applicable safety standards (i.e., ANSI A156.10/A156.19) 

upon completion of installation.

 

Summary of Contents for Securitron WSS

Page 1: ...5 kg REGULATORY Electromagnetic compatibility EMC according to 2004 108 EC FCC G9B 21016 IC 4680A 21016 Precautions 1 SHUT OFF power to header before attempting any wiring procedures 2 MAINTAIN a clean and safe environment when working in public areas 3 Constantly BE AWARE of pedestrian traffic around the door area 4 Always STOP pedestrian traffic through the doorway when performing tests that may...

Page 2: ...cable and depending on the type of door installation NOTE 1 The weather resistant foam is used as a protective barrier against the elements NOTE 2 The plastic adapter ring enables the double gang face plate to attach to various plastic and metal gang boxes NOTE 3 If using a metal electrical box do not allow contact between the sensor and the box to prevent shorting the device 2 ENSURE placement of...

Page 3: ...tch down factory default detection activates the relay for 0 5 to 30 seconds relay will hold as long as detection occurs 4 LED mode switch determines if LED illuminates when in detection or when not in detection switch up factory default LED on when sensor is NOT in detection LED off when in detection switch down LED on when sensor is in detection LED off when not in detection Troubleshooting PROB...

Page 4: ...lay connection FCC Approval This device complies with Part 15 of the FCC Rules and with RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation IMPORTANT NOTE Changes or modifications to this equipment that are no...

Reviews: