background image

Commissioning the GSM-WiFi U - Standalone contd.

Press the 

Scan WiFi Networks

 icon.

The system will take about 30 seconds to scan the premises for 
WiFi routers. When complete, select the router in question, enter 
the router’s password and press 

Connect

.

Then go to 

COMMUNICATORS 

and select 

WiFi

.

sheehan home (Signal Level: 5)

7

            

Note:

 When the unit is successfully connected, 

WiFi Status 

LED 

            will flash green. Each flash represents 20% WiFi coverage (e.g. 4 
            flashes = 80%).

!

Summary of Contents for SecureComm HKC GSM-WIFI U

Page 1: ...www hkcsecurity com Security Safe Secure An ASSA ABLOY Group brand Universal GSM WiFi IP Communicator ...

Page 2: ...ges is dependent on the telecom service provider HKC Security Ltd cannot guarantee successful messaging Messages which remain undelivered when the validity period expires are discarded The validity period is the time the message is submitted plus 12 hours COPYRIGHT HKC Security Ltd All Rights reserved No part of this publication may be reproduced transmitted stored in a retrieval system or transla...

Page 3: ...forces the unit to establish a GSM link to the SecureComm server in the background Initially the GSM Status LED flashes orange for 15 minutes Here you will find an intuitive series of prompts which sets up basic account details Once the process is complete you will be issued with an installation ID number The second phase involves physically configuring the system i e powering up the GSM WiFi Unit...

Page 4: ...ew GSM WiFi Universal option Then either type in the serial number or scan the QR code pattern from the label fitted on the circuit board Note To scan the pattern press the Scan QR icon and place the phone s camera in front of the label The Serial Number box will auto populate Type in the SecureComm installation ID number the one you got when you established the billing details page 3 Commissionin...

Page 5: ...code The 0 digit may be used A SecureComm Password chosen by the installation engineer must also be entered The minimum length of the password is 4 characters Maximum length is 16 The characters can be letters or numbers when the HKC APP is being set up Keep this password safe for the moment it will be required Finally press the Connect icon Commissioning the GSM WiFi U Standalone contd 1234567 12...

Page 6: ... connectivity it should also be connected to a WiFi network Therefore You will see the new site added to your customer list To add WiFi connectivity click on the customer in question in this example Sheehan s Then click on the red cloud icon to connect to the communicator 1234567 Sheehan s Vincent Walsh Mary Sheehan Serial Number SecureComm ID Type Version 1 0 0 19 GSM WiFi Universal 1234567 10081...

Page 7: ...n the premises for WiFi routers When complete select the router in question enter the router s password and press Connect Then go to COMMUNICATORS and select WiFi sheehan home Signal Level 5 7 Note When the unit is successfully connected WiFi Status LED will flash green Each flash represents 20 WiFi coverage e g 4 flashes 80 ...

Page 8: ...this manual and the password chosen by the installation engineer from page 5 of this manual When done press the Connect icon The HKC APP is now ready to go To login to the site enter the User Code that was programmed on page 5 The GSM WiFiU unit is now live and ready for the 3rd and final phase which involves the end user downloading the HKC APP from Google play or Apple s App Store Note To find t...

Page 9: ... unit Output 1 is a programmable Normally Open output that by default follows the onboard tamper switch and will also open if a fault is detected on the GSM or Wi Fi path This output will be closed when the tamper is closed and there are no faults detected on the communication paths This output will open if power is lost to the unit These outputs are fully programmable through the SmartLink700 App...

Page 10: ...rogrammed for Line Fault Zone programmed for Key Note Given that a GSM or WiFi fault is more likely than a tamper activation choose this zone for Line Fault Note Make sure these are programmed as positive trigger Note Choose either input 3 or 7 depending on your monitoring company s preferred channel for a verified alarm signal 10 Remove the mains and battery supply before fitting the GSM WiFiU un...

Page 11: ...then you will need to set it up as per page 8 However one advantage of connecting the unit to a SecureWatch panel is that the communicator can be commissioned through the panel s engineering menu structure You can not use the SmartLink700 app for this task Wire the GSM WiFiU communicator to the SecureWatch panel as illustrated in the next page internet browser and type securecomm hkc ie as before ...

Page 12: ...t Z6 Z7 Wiring to SecureWatch Panel 12V 12 Remove the mains and battery supply before fitting the GSM WiFiU unit Note For SW 812 make sure software is V7 32 or later For SW 16120 make sure software is V2 0 or later Note For tamper purposes wire as illustrated and programme the zone input of your choice as a Tamper go to Zone Types in the Zone Menu ...

Page 13: ...o enable the GSM and WiFi capabilities of the device 2 IP Address 2 Disable GSM 2 Disable WiFi 2 Fault Delay 2 Fault Delay 2 Monitor Faults 2 WiFi 1 DHCP Enabled 1 Status 1 Status 1 Monitor Signal Yes Yes 10m 10m Yes Yes Yes 1 Monitor Signal 1 IP Settings 1 GSM 5 DNS Server 4 Gateway 4 GMS Network Scan 4 WiFi Network Scan 4 Tamper 3 Subnet Mask 3 Options 3 Options 3 Jam Detect 3 Tamper If you enab...

Page 14: ...ay 1 should be wired to a Zone programmed as Tamper or wired to a Tamper loop on a spare Zone Turning off this option will disable the tamper switch and keep Relay 1 permanently closed The GSM unit can detect and flag attempts at jamming the GSM signal In areas where the network is prone to high levels of radio noise this feature can be turned off by deselecting Jam Detect Note If you are using a ...

Page 15: ...ure By default it is set to YES You can delay the notification of a fault by going to the Fault Delay sub menu and keying in a delay time in minutes Useful in areas of poor WiFi coverage that are prone to occasional brief dropouts By default it is set to 10 minutes In this sub menu you can turn off the Tamper signal from the communicator By default it is on i e YES 96221 WiFi Status 96222 Disable ...

Page 16: ...account number and put it into Account section here Note Remember to select this option in the securecomm hkc ie portal There is a virtual keypad available in the HKC APP You may want to disable this feature in which case you set Virtual Keypad to NO It is YES by default Normally the HKC APP will notify you of alarms and faults from your system You may want to disable this feature in which case yo...

Page 17: ...future Select Test Start and key in the hours and minutes of the first test call Following on from the first test call subsequent test calls can be made at a set interval Select the number of hours of this interval by keying in a number in Test Period These settings allow the installer to tailor poll fault messages being sent to the ARC Depending on whether just one or both of the GSM WiFi communi...

Page 18: ...keypad This AVI Message is freely programmable The default message is Call Monitoring i e Call the monitoring centre 96337 AVI Commissioning GSM WiFi U SecureWave Mode So far we have dealt with commissioning a standalone and a SecureWatch system In this section we will look at commissioning using a SecureWave panel You will need to go to your And if you want to control the system via the HKC APP t...

Page 19: ...LL STROBE OUTPUTS Aux 12V REMOTE RKP EXP 1 B A 2 T A M P S A B B R E T N H O L D D C B A Plug Comms Card onto either Serial Port SW 10270 Control Panel 12V Z6 Z8 Z9 Z10 Z7 Z5 Z4 Z3 Z2 Z1 Remove the mains and battery supply before fitting the GSM WiFiU unit Note For SW 10270 make sure software is V4 2 or later ...

Page 20: ...st the device the SecureComm service in the background Note You have to manually Scan for WiFi if you opt to only enable the WiFi system You will be prompted to key in the installation ID number the one you got when you established the billing details page 3 You will then be prompted accept a randomly generated 10 digit alphanumeric This password can be changed by pressing NO Note Passwords can be...

Page 21: ...onal brief dropouts By default it is set to 15 minutes In this sub menu you can turn off the Tamper signal from the communicator By default it is on i e YES The GSM unit can detect and flag attempts at jamming the GSM signal In areas where the network is prone to high levels of radio noise this feature can be turned off by deselecting Jam Detect Note If you are using a GSM WiFiU via the SecureComm...

Page 22: ...iFi coverage that are prone to occasional brief dropouts By default it is set to 10 minutes In this sub menu you can turn off the Tamper signal from the communicator By default it is on i e YES 9221 WiFi Status 9222 Disable WiFi 9223 Options 9223 Options 92231 IP Settings 92232 Monitor Faults 922321 Monitor Signal 922322 Fault Delay 922323 Tamper This sub menu offers an overview of the SecureComm ...

Page 23: ...account number and put it into Account section here Note Remember to select this option in the securecomm hkc ie portal There is a virtual keypad available in the HKC APP You may want to disable this feature in which case you set Virtual Keypad to NO It is YES by default Normally the HKC APP will notify you of alarms and faults from your system You may want to disable this feature in which case yo...

Page 24: ...ture Select Test Start and key in the hours and minutes of the first test call Following on from the first test call subsequent test calls can be made at a set interval Select the number of hours of this interval by keying in a number in Test Period These settings allow the installer to tailor poll fault messages being sent to the ARC Depending on whether just one or both of the GSM WiFi communica...

Page 25: ...Signals Continued The AVI Time audio visual indicator in seconds is freely programmable and is the length of time this feature remains active when triggered If a valid signal is communicated to a ARC after the system has been unset the AVI message will display on the keypad and the keypad buzzer will activate to advise the customer to contact their monitoring station During an AVI event a message ...

Page 26: ...ted to GSM WiFi Router Constant on off AMBER flashing connecting to SecureComm Server Enabled connected to SecureComm Server 1 Green Flash 20 GSM WiFi Signal Strength 2 Green Flashes 40 GSM WiFi Signal Strength 5 Green Flashes 100 GSM WiFi Signal Strength IP Monitoring Path is Grade III compliant i e EN 50136 1 SP3 DP2 by going with 10 minute polling option available to purchase at normally the po...

Page 27: ......

Page 28: ... your security system For Further information in relation to any of our products please contact us at HKC Security Ltd Parkway Business Centre Ballymount D24 WY49 Ireland T 353 1 456 7007 F 353 1 456 8332 E sales hkc ie or visit us at www hkcsecurity com An ASSA ABLOY Group brand ...