8 1-800-810-WIRE • www.sargentlock.com • A7855C
Copyright © 2014, Sargent Manufacturing Company
, an ASSA ABLOY Group company
. All rights reser
ved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
01/31/14
Profile Series v.G1.5/LK Mortise Lock
1. Insert lock body into mortised cutout (Fig. 3A).
2. Hold lock body loosely in place with (2) lock
body screws.
Note: Do not completely tighten screws at this time.
Step #3 – Install Lock Body
Fire-rated doors require a fire stop plate on
the outside of the door (Fig. 4A).
1. Drill (2) 1/8” x 1-1/4” deep holes
in the door if not already present.
Refer to template for fire-stop
prep locations.
2. Attach with flap up and
out using (2) #8 x 1/2”
self-tapping screws for
wood and metal doors.
B. Weather Conduit
(P/N 52-2847)
Install weather conduit on
NON FIRE-RATED
exterior
doors only.
1. Carefully insert the weather
conduit into the ribbon cable
hole on the inside of the door
(Fig. 4B).
2. Place the O-ring around the
weather conduit on the out-
side and up against the door
(Fig. 4C).
of 1-1/2”
Diameter
(2) 1/8” Diameter
Holes Required
Fire Stop Plate
Slot
(2) Self Tapping
Screws #8 x 1/2”
for Wood and
Metal Doors
Fig. 4A
A. Fire Stop Plate (P/N 53-0033)
7/8”
1-1/2”
Outside of Door
Non-Cylinder Side
Fig.4B
Ribbon Cable Hole
Fig.4C
O-Ring
Outside of Door
Step #4 – Exterior Door Options
(2) #12-24 x 1/2”
Flat Head Screws
(Metal Doors)
(2) #12 x 1-1/4”
Flat Head Screws
(Metal Doors)
Fig. 3A
Harness exits
Non-Cylinder side