24 1-800-810-WIRE • www.sargentlock.com •
A7765C
Copyright © 2018, Sargent Manufacturing Company
, an ASSA ABLOY Group company
. All rights reser
ved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
01/31/18
Profile Series v.S1 PoE Exit Device
For exterior applications, use a gasket (part number 82-0500)
between escutcheon and outside door surface.
To apply weatherseal gasket:
1. Carefully remove the backing from the gasket (Fig. 9A).
2A. For 12- fire rated devices:
Feed keypad ribbon cable/connector
from outside of door through gasket and fire stop plate.
2B. For non-12- exit devices:
Feed keypad ribbon cable/connector
through the gasket and then through the conduit hole in door.
Note: Install ribbon cable with cable exiting down.
3. Apply gasket to escutcheon:
a. Starting in one place, press the adhesive side
of the gasket firmly against the escutcheon.
b. Work around the escutcheon,
pressing the sticky side of the
gasket firmly against the
escutcheon edge.
c. The gasket should be aligned so
that all edges of the escutcheon
are covered.
4. Place the outside escutcheon against,
while directing mounting posts
through the door.
Step #9 – Attach Gasket and Install Outside Escutcheon
Gasket 82-0500
Fig. 9A
Fire
Stop
Plate
Weatherseal
Gasket
Fig. 9B
Keypad
Ribbon
Ground
Harness
Antenna