14 1-800-810-WIRE • www.sargentlock.com •
A7765C
Copyright © 2018, Sargent Manufacturing Company
, an ASSA ABLOY Group company
. All rights reser
ved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
01/31/18
Profile Series v.S1 PoE Exit Device
1. Route ET harness through wire run channel for wood doors (Fig. 3A)
and through access hole for metal doors (not shown).
Note: Make sure no wires are pinched.
2. Before securing chassis, connect ground wire harness:
a. Spade connector of ground ring terminal wire fits
through the hole (beneath the top screw) in the
chassis and connects to lug on ground
harness (Fig. 3B Detail).
b. Route the ground ring terminal and secure
through the top center hole with the top
1/4-20 x 2-3/8" flat head machine
screw (Fig. 3B Detail).
3. Engage ET spindle in the hub of exit
device chassis.
4. Secure chassis and ET with (2) 1/4-20 x
2-3/8" flat head machine screws.
5. Connect ET harness and connector
from chassis (Fig. 3C).
3 – Secure Inside Trim and Chassis
4
Inside of Door
Fig. 3A
Lug and Spade
Connector
1
3
Ground
Ring
Terminal
Unused
5
Route wires under exits
chassis, and out wire route slot
Fig. 3B Detail
2a
2b
Ground Harness
2
Outside of Door
4
Ground Ring
Terminal
(Unused)
Fig. 3C
Showing Wood Door Template
With Cylinder Hole