7

800-810-WIRE (9473) • www.sargentlock.com • A7755A

Profile Series v.G1 Cylindrical Lock

 

Copyright © 2004, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. 

 

Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibite

d.

1.  Insert key, rotate 45° clockwise and hold
2.  Depress lever retainer with push pin tool (provided).

7. Remove Outside Lever Only

1.  With outside lever in hand- use standard  

pliers, pull out cylinder retainer.
2.  Remove key and cylinder from lever.
3.  Insert new cylinder.*
4.  Secure by pressing cylinder retainer  

  flush with self.*

* NOT SHOWN

How to Change Cylinder  

(if required)

45º

Feed wires and

connector in  

routed channel

Routed channel for

wood door only

Screws 

partially

tightened

Inside of

door

Outside of

door

Feed wires and 

connector if 

wood door

Routed channel for

wood door only

Inside nut

Inside plate

Screws 

partially

tightened

1A.  If wood door, feed wires up through 

the   routed channel as shown.
1B.  If metal door, feed wire and connector  

 

through inside of door and out hole on  

 

outside of door. * 

2.   Attach inside rose assembly and    

 

spacer bushing and secure with  

 

screws shown

6. Securing the Lock to Door

Washers

(only 30- prefix)

Cylinder

Retainer

Cylinder

Outside

Lever

Key

A7755A.indd   7

11/9/18   12:05 PM

Summary of Contents for Sargent Profile G1 Series

Page 1: ...argent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited FOR ASSISTANCE CONTACT SARGENT AT 800 727 5477 or www sargentlock com A7755A indd 1 11 9 18 12 05 PM ...

Page 2: ...rates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that the interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment o...

Page 3: ...s 01 02 are utilized for Master Code and Supervisory Code respectively This product is operated by six 6 AA alkaline batteries Non volatile memory Motor driven battery operated Battery operated with 6 AA Alkaline Low battery alert 4 chirps after code entry External remote request to enter Master Emergency or Supervisory code will unlock door when low battery has expired 100 LK or 2000 G1 LU G1 PK ...

Page 4: ...nufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited 1 17 21 Optional 21 21 10 11 13 15 6 2 7 12 18 24 16 9 14 7 21 3 25 23 5 24 19 4 5 Parts Breakdown A7755A indd 2 11 9 18 12 05 PM ...

Page 5: ...gy G1 TU G1 TP G1 TA 6 10 0019 Cylinder Spacer 1 7 10 0792 Spacer Bushing 2 9 10 3048 Inside Rose Spring Assembly 2 10 10 0524 B Outside Lever Standard Cylinder 1 10 2205 J Outside Lever Standard Cylinder 1 10 0502 L Outside Lever Standard Cylinder 1 10 0546 P Outside Lever Standard Cylinder 1 10 0525 B OutsideLever 30 To Accept Schlage Cylinder 1 10 2206 J Outside Lever 30 To Accept Schlage Cylin...

Page 6: ...s Deadbolt Guardbolt Latchbolt Front Top Lock w cylinder Override Shown End Cap Installation Instructions 6 1 Verify Hand and Bevel of Door 2 Door Preparation Prepare door according to appropriate template see website www sargentlock com For metal door template see 4531 and 4532 For wood door template see A7456 and A6719D Prior to installation all holes must be free of burrs debris and sharp edges...

Page 7: ...h two screws but DO NOT tighten completely at this time 3 Attach Fire Stop Plate with two screws Note Required for all Fire Rated doors Centerline of latch front and strike Screws 2 8 32 x 3 4 8 Dia holes x 1 4 Deep red olt 1 1 2 2 1 8 Dia holes required 7 8 Fire stop plate Through bolt hole 2 2 Self tapping screws 8 x 1 2 long for wood metal doors Slot C L of 1 1 2 Dia e Lockbody hole Latchbolt d...

Page 8: ... and door thickness Through bolt location rotate outside rose to match door Door thickness rotate outside rose to align door thickness marking with lockbody edge Spacer bushing remove and realign to fit into back of lever 5 Lock Installation IMPORTANT Door must remain open during installation Use door stop IMPORTANT Lockbody must be centered in the door 3 1 3 4 thick door 2 thick door Through bolt...

Page 9: ... pliers pull out cylinder retainer 2 Remove key and cylinder from lever 3 Insert new cylinder 4 Secure by pressing cylinder retainer flush with self NOT SHOWN How to Change Cylinder if required 45º Feed wires and connector in routed channel Routed channel for wood door only Screws partially tightened 1A If wood door feed wires up through the routed channel as shown 1B If metal door feed wire and c...

Page 10: ...body 4 Slide the outside lever onto tube with key horizontal toward latch Rotate key 45 degress clockwise 5 Push lever until lever catch is engaged Outside of door Ground wire Inside lever Inside of door Inside rose 8 32 Flat head screw Weather Seal Gasket C Lockbody harness E Keypad harness A Ground wire Latch screws F Controller connector Latch screws Cylinder spacer Ribbon cable with connector ...

Page 11: ... cover to inside escutcheon making sure to line up tabs with retaining slots in battery cover Secure with security screw Ref Fig 4 Security screw Security tool 01 0297 included Outside of door Front plate 2 Flat head screws 3 Place 6 AA batteries into the compartment being careful to align polarity properly Ref Fig 2 Inside of door Battery cover Battery keeper Lockbody screws Polarity Polarity Top...

Page 12: ...ocess for the battery keeper The antenna board must be carefully moved to access the upper through bolt screw Care should be taken to prevent damage to the antenna retaining tabs during this process Press the two tabs away from the antenna board and lift the board off the mounting posts Insert the flat head through bolt and secure the escutcheon in place After tightening the top through bolt repla...