Assa Abloy Sargent Profile G1 Series Installation Instructions Manual Download Page 10

Outside of

door

Ground

wire

Inside lever

Inside 

of door

Inside rose

8-32 Flat head 

screw

Weather

Seal

Gasket

(C) Lockbody

harness 

(E) Keypad 

harness 

(A)  

Ground  

wire 

Latch

screws

(F) Controller 

connector 

Latch  

screws

Cylinder 

spacer

Ribbon 

cable with 

connector

Outside 

Escutcheon

Fire stop 

plate

Weather  

seal gasket

8

800-810-WIRE (9473) • www.sargentlock.com • A7755A

Profile Series v.G1 Cylindrical Lock

Copyright © 2004, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. 

 

Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibite

d.

NOTE: For exterior applications, use weather seal gasket part 
# (10-0649) between escutcheon and outside door surface
1A.  For fire rated doors only feed ribbon cable connector and   

 

ground wire from outside of door through weather seal gasket  

(if used) then fire stop plate.
1B.  For non-fire rated doors only, feed ribbon cable connector   

 

and ground wire from outside of door through weather seal  

 

gasket (if used), then conduit sleeve in door (not shown).*

2.  Slide the outside escutcheon over the lock, and hold  

 

 

the escutcheon to the door surface

3.  Verify white plastic cylinder spacer is inserted into horizontal  

 

slot of lockbody.*

4.  Slide the outside lever onto tube with key horizontal  

 

(toward latch). Rotate key 45 degress clockwise.

5.  Push lever until lever catch is engaged

Outside of

door

Ground

wire

Inside lever

Inside 

of door

Inside rose

8-32 Flat head 

screw

Weather

Seal

Gasket

(C) Lockbody

harness 

(E) Keypad 

harness 

(A)  

Ground  

wire 

Latch

screws

(F) Controller 

connector 

Latch  

screws

Cylinder 

spacer

Ribbon 

cable with 

connector

Outside 

Escutcheon

Fire stop 

plate

Weather  

seal gasket

8. Installation of Outside Escutcheon and Lever

9. Inside Escutcheon and Lever

1.  Remove black battery cover from the escutcheon with security wrench (provided).
2.  Connect ground wire to terminal E3 (Fig. 1), connect keypad harness (Fig. 2) to controller, and connect lock   

  body motor harness (Fig. 3) to motor connector.
3.  Feed all excess wire through inside door hole and/into outside escutcheon cavity, being careful not to pinch 

wires.
NOTE: Connectors go on only one way, do not offset connector and be sure they are completely sealed.
4.  Insert two #8-32 screws (Fig. 2) through top and bottom of inside escutcheon and thread into outside escutcheon.  

  Straighten escutcheons and tighten securely, being careful to avoid pinching wires.
NOTE: For RF Technology versions (G1-TU, G1-TP, G1-TA), refer to Section 8 to install through-bolt screws.

5.  Slide the Inside Lever onto the tube.
6.  Tighten two latch screws completely.

Figure 1

Figure 3

Figure 2

* NOT SHOWN

A7755A.indd   8

11/9/18   12:05 PM

Summary of Contents for Sargent Profile G1 Series

Page 1: ...argent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited FOR ASSISTANCE CONTACT SARGENT AT 800 727 5477 or www sargentlock com A7755A indd 1 11 9 18 12 05 PM ...

Page 2: ...rates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that the interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment o...

Page 3: ...s 01 02 are utilized for Master Code and Supervisory Code respectively This product is operated by six 6 AA alkaline batteries Non volatile memory Motor driven battery operated Battery operated with 6 AA Alkaline Low battery alert 4 chirps after code entry External remote request to enter Master Emergency or Supervisory code will unlock door when low battery has expired 100 LK or 2000 G1 LU G1 PK ...

Page 4: ...nufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited 1 17 21 Optional 21 21 10 11 13 15 6 2 7 12 18 24 16 9 14 7 21 3 25 23 5 24 19 4 5 Parts Breakdown A7755A indd 2 11 9 18 12 05 PM ...

Page 5: ...gy G1 TU G1 TP G1 TA 6 10 0019 Cylinder Spacer 1 7 10 0792 Spacer Bushing 2 9 10 3048 Inside Rose Spring Assembly 2 10 10 0524 B Outside Lever Standard Cylinder 1 10 2205 J Outside Lever Standard Cylinder 1 10 0502 L Outside Lever Standard Cylinder 1 10 0546 P Outside Lever Standard Cylinder 1 10 0525 B OutsideLever 30 To Accept Schlage Cylinder 1 10 2206 J Outside Lever 30 To Accept Schlage Cylin...

Page 6: ...s Deadbolt Guardbolt Latchbolt Front Top Lock w cylinder Override Shown End Cap Installation Instructions 6 1 Verify Hand and Bevel of Door 2 Door Preparation Prepare door according to appropriate template see website www sargentlock com For metal door template see 4531 and 4532 For wood door template see A7456 and A6719D Prior to installation all holes must be free of burrs debris and sharp edges...

Page 7: ...h two screws but DO NOT tighten completely at this time 3 Attach Fire Stop Plate with two screws Note Required for all Fire Rated doors Centerline of latch front and strike Screws 2 8 32 x 3 4 8 Dia holes x 1 4 Deep red olt 1 1 2 2 1 8 Dia holes required 7 8 Fire stop plate Through bolt hole 2 2 Self tapping screws 8 x 1 2 long for wood metal doors Slot C L of 1 1 2 Dia e Lockbody hole Latchbolt d...

Page 8: ... and door thickness Through bolt location rotate outside rose to match door Door thickness rotate outside rose to align door thickness marking with lockbody edge Spacer bushing remove and realign to fit into back of lever 5 Lock Installation IMPORTANT Door must remain open during installation Use door stop IMPORTANT Lockbody must be centered in the door 3 1 3 4 thick door 2 thick door Through bolt...

Page 9: ... pliers pull out cylinder retainer 2 Remove key and cylinder from lever 3 Insert new cylinder 4 Secure by pressing cylinder retainer flush with self NOT SHOWN How to Change Cylinder if required 45º Feed wires and connector in routed channel Routed channel for wood door only Screws partially tightened 1A If wood door feed wires up through the routed channel as shown 1B If metal door feed wire and c...

Page 10: ...body 4 Slide the outside lever onto tube with key horizontal toward latch Rotate key 45 degress clockwise 5 Push lever until lever catch is engaged Outside of door Ground wire Inside lever Inside of door Inside rose 8 32 Flat head screw Weather Seal Gasket C Lockbody harness E Keypad harness A Ground wire Latch screws F Controller connector Latch screws Cylinder spacer Ribbon cable with connector ...

Page 11: ... cover to inside escutcheon making sure to line up tabs with retaining slots in battery cover Secure with security screw Ref Fig 4 Security screw Security tool 01 0297 included Outside of door Front plate 2 Flat head screws 3 Place 6 AA batteries into the compartment being careful to align polarity properly Ref Fig 2 Inside of door Battery cover Battery keeper Lockbody screws Polarity Polarity Top...

Page 12: ...ocess for the battery keeper The antenna board must be carefully moved to access the upper through bolt screw Care should be taken to prevent damage to the antenna retaining tabs during this process Press the two tabs away from the antenna board and lift the board off the mounting posts Insert the flat head through bolt and secure the escutcheon in place After tightening the top through bolt repla...

Reviews: