The following are the input and output connector designations.
Harness
Circuit
Connector
Board
Input/
Harness
Function
Pin No.*
Pin No.
Output
Wire Color
8-2
J1-1
input
Red
+24VDC power
8-1
J1-2
input
Black
-Return
8-3
J1-4
input
White
8-5
J1-5
input
Orange
External inhibit - disarm unit from
i/s or o/s (key switch, card reader, keypad)
8-6
J1-6
input
Blue
Door position sensor (Door Status/Monitor)
8-4
Chassis
Ground
Green
ESD (Earth) Ground
8-7
J1-8
output
Brown
-Return Magnet -
8-8
J1-10
output
Red
+24VDC Magnet
N.O.
N.C.
Remote Reset
N.O.
*Example: 8-2 is the 8-pin connector position #2