A.   Verify frame and door installation.

1. 

Determine if right hand or left hand 

installation. (Figure 1)

2.  Verify frame is square by using a 

carpenter’s square. (Figure 2)

 

3.  Note if gaps between door and frame are 

consistent. Gap should be 1/16" (1.6) at 

jamb and header.

 

4.  Using supplied templates, confirm all 

dimensions of cut-outs.

Installation 

Figure 1 

Figure 2 

Figure 3 

Left Hand Shown

B.   Install closer.

1.  Attach wood mounting clips to closer 

with 1/4-20 x 5/8" FHPMS screws 

provided.

 

2.  Install closer in prepped frame with four 

(4) 14 x 1-1/2" FHPWS mounting screws 

provided.  (Figure 3)

 

 

NOTE: Mounting plate should be flush 

with frame soffit.

D.   Attach arm.

C.   Install cover plate.

1. 

Install cover plate to closer mounting 

plate with six (6) 6-32 x FHPMS 

mounting screws provided. (Figure 4)

Figure 4 

Figure 5 

1.  Using provided 5/32" hex wrench and 

1/4-20 x 3/4" Allen Drive with Patch 

screw and washer, attach arm to closer 

spindle. (Figure 5)

 

 

IMPORTANT: Arm should rest at 

15° away from door side of closer 

mounting plate. Arm always rotates 

in direction of door.

Summary of Contents for RIXSON W91DCP

Page 1: ...ause cancer and birth defects or other reproductive harm For more information go to www P65warnings ca gov WARNING Model W91DCP Left Hand shown 4 1 2 x 4 1 2 Butt or 3 4 Offset Pivot Hung consult fact...

Page 2: ...ce Checkmate or other door stop supplied by others is strongly recommended to avoid damage to door closer and adjacent property Doors should be hung on ball bearing or anti friction hinges pivots Door...

Page 3: ...mplates confirm all dimensions of cut outs Installation Figure 1 Figure 2 Figure 3 Left Hand Shown B Install closer 1 Attach wood mounting clips to closer with 1 4 20 x 5 8 FHPMS screws provided 2 Ins...

Page 4: ...alling track to door 2 Install track and if necessary optional spacer replacement application only consult factory using four 4 14 x 1 5 8 FHPWS screws provided Figure 7 G Attach arm to track Non Hold...

Page 5: ...as a dead stop NEVER fully open valves Valves will leak Do not use a power drill Warranty will be void Closing Force Adjustment If additional force is needed use 3 8 hex wrench to adjust closing forc...

Page 6: ...and all adjustments are complete install removable stop NOTE DO NOT drill holes into closer cover plate You ve now installed the Model W91DCP Overhead Concealed Closer Troubleshooting Symptom Cause Re...

Page 7: ...CUTOUT STOP SIDE ONLY A TOP OF DOOR 5 16 8mm 1 4 6mm NOTES FOR 180 OPENING MAX ALLOWABLE BUTT 1 HINGE SIZE IS 5 X 5 MINIMUM STOP THICKNESS 1 2 2 1 8 DOOR TO SOFFIT CLEARANCE REQUIRED 3 REINFORCING PE...

Page 8: ...CONSTRUCTION A 1 5 8 41mm CLOSER HEIGHT OPTIONAL SPACER NOTES FOR PIVOT INSTRUCTIONS OR DETAILS SEE 1 PIVOT TEMPLATE FOR USE WITH RIXSON PIVOT MODEL 180 SERIES MINIMUM STOP THICKNESS 1 2 2 1 8 DOOR T...

Reviews: