background image

ASSA Pando display reader

   

  

 

 

 

 

 

About ASSA Pando 

ASSA Pando reader is a combination reader, supports both Hi-O protocol 
and RS485-based protocols.  
By default reads the Pando reader serial number on the cards but ASSA 
recommends that readers configured for the sector reading to achieve a 
higher level of security. The programming are made with a customer specific 
Setup card. Mifare classic, Desfire card and iClass is supported. 

 

 

Hi-O Installation  

Hi-O devices are easy to install, all devices are connected in parallel and 
just using four threads. Units of Hi-O bus usually gets its supply voltage from 
the DAC 530II, DAC564II or LCU9101.  

 

Connect the CAN bus the CAN-H and CAN-L and power out to the CAN bus 
at the next two terminals in the DAC/LCU, +12 V and 0V.  
Connect one or more ASSA Pando readers and motor lock and RTE buttons 
to the CAN bus. Set the SIO bus address to 00 in the reader and set the 
function selection 1 for in or out reader.  

 

Installing Pando display on the SIO bus.  

Connect the SIO bus to the A and B terminals and power supply to the 
reader to + V and 0V connections (+24 V and 0V).  
Set SIO bus address from 1-99, depending on which address is available on 
the SIO bus.  

 

Indications for Hi-O mode = SIO address 0  

Green: Lights when the reader is uninitialized at  
the Hi-O bus, Pando reader is not locked to a specific Hi-O bus.  
Red: lights when Pando reader is locked to a specific  
Hi-O bus, red indicates that the reader is locked and encrypted.  
 

Indications for SIO mode address 1-99  

Green: TX, Sending data   
Red: RX, Receiving data 
 

Table for the function selection via the keypad 

 

 

Key 

function 

Inside/outside reader 
On = Inside  
Off = Outside 

Key beep, beep when keystrokes and major & 
minor signal at invalid/valid card. 

Card beep, Beep at card read 

Light ON, Keypad always lit. 

Light Code, Keypad lit when the indication for 
door code/PIN code is activated 

 

Settings and addressing   

 

 

Set Conf. Dip in the ON position  

 

Then press the “A” 

 

The menu lights up on the display  

 

Switching function choices (Fx) On/Off by pressing the 
respective number key. 

F1 = Numeric Key 1, etc .

(See table for functions).  

 

Then press the "B", to address.  

 

Enter the address using the numeric keys.  
Hi-O Address = 00  
SIO bus Address 1-99  

 

Press "B" to save  

 

Set Conf. DIP to OFF  

 

Restart the reader.  

 

Change Address / Factory Reset of SIO connected 
readers. 

 

Set Conf. Dip in the ON position  

 

Turn on the reader  

 

Then press "B", to address.  
 
To factory reset the communication key.  

Needs to be done if the address changes or when you changed 
the database on the server or starting over with an empty 
database.  
See ARX manual for more information. 

o

 

Enter address 00 (Restores crypto key) 

o

 

Press "B" to save (crypto key restored) 

o

 

Then press "B" again, to address. 

 

Enter the address 1-99 

 

Set Conf. DIP to OFF  

 

Press the "B" to save, (Readers restart) 

 

Unlock a locked Hi-O reader.  

Normally unlocks the reader through the DAC or the LCU that is connected to, but if you 
need to unlock the reader without the DAC or the LCU it has been locked by using the 
following steps.  
 

 

Turn on the power to the reader.  
Red LED illuminates solid, indicating that the reader is locked.  

 

Turn Conf. DIP ON and OFF at one second intervals 6-8 times.  

 

When the reader switches from red to green is it unlocked. 

 

 
Configuration of sector reading  

1.

 

Cut and connect the power to the reader, by lifting the “plug able” terminal and 
putting it back. 

2.

 

Green indication flashes for 90 seconds. 

3.

 

Show the Setup card to the reader, before it stops flashing. 

4.

 

The reader indicates that the programming is finished with a “chirp” and the 
green indication is unlit. 

5.

 

The reader is now programmed with the encryption keys of the site. 

 

Note!

  If a card presented to an ASSA Pando display reader doesn’t have encryption keys 

corresponding with the reader the reader will not indicate that anything is wrong and the 
reader will not send any data. 

Technical specifications 

Power supply 

12-24V DC  

Power Consumption 

12V:  65 mA Max 130mA 

Recommended cable 

EKKX 2x2x0,2 

Hi-O Cable length 

Total:     

Max. 50 m 

Branch: 

Max. 10 m 

Dimensions 

H 185 mm, W 69 mm, D 22 mm. 

 

Terminal 

CH 

Can H 

Connection to the Hi-O bus (DIP6 = ON) 

 LCU9101, DAC530II or DAC564II 

CL 

Can L 

+V 

+ V (12-24 DC) 

Power to the reader. 

0V 

0V 

RS485 

Connecting to ASSA SIO bus (RS485) 

RS485 

NC 

Free 

Termination  

If the reader is finally on the SIO bus, the termination shall be activated.  
Set DIP 2 "Term" in the ON position.  

IS559686940C 