58
EN
Installation
Installing the electric multi-point lock 819N
1
Adjust the closing direction of the control latch (“Adjusting the closing direction of the latch”, page 59).
2
Adjust the panic side (“Changing the panic side”, page 60).
3 Fasten
the
electric multi-point lock 819N
in the lock pocket.
4
Fasten the lock fittings.
5 Check
the
electric multi-point lock 819N
for ease of movement.
Once the striking plate has been mounted, the
electric multi-point lock 819N
is ready for use.
Mounting the striking plate
1
Finish the striking plate pocket and all holes or finish a customer-provided striking plate (“Production
of customer-provided striking plates”, page 66).
2
Clean the striking plate pocket and all holes by blowing them out or vacuuming.
3
Screw in the appropriate locking plate for the
electric multi-point lock 819N
to be screwed in.
4 Check
the
electric multi-point lock 819N
for ease of movement.
The
electric multi-point lock 819N
is ready for operation.
Installing fittings and locking cylinders
1
Install the fittings.
2
Insert the locking cylinder and ensure that the locking cylinder nose is in the centre position (Fig. 15).
3
Fix the locking cylinder into place with the fixing screw.
The
electric multi-point lock 819N
is completely installed.
Testing the electric multi-point lock 819N
1
Test all functions of the
electric multi-point lock 819N
.
2
Check whether the latch and auxiliary latch bolt of the lock are pushed back by the same impact edge.
3
Check whether all bolts can freely extend and retract without transverse shear stress after installation
(Fig. 7).
The
electric multi-point lock 819N
is completely installed and has been tested for functionality.
Fig. 7 :
No transverse shear
stress on the bolt after
installation
F
Q
= 0 N
F
Q
= 0 N
min. 2
min. 2
Striking plate
Face plate
Prepare the lock
Fasten the lock
Fasten the appropriate
striking plate
Fasten the locking
cylinder with the
cylinder fixing screw
Check for complete
functionality