Copyright © 2007, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
80-9377-1204-020 (04-14)
1
ASSA ABLOY
ASSA ABLOY
Installation Instructions
7500H Series
An incorrectly installed or improperly
adjusted door closer can cause property
damage or personal injury. These instructions
should be followed to avoid the possibility
of misapplication or misadjustment.
CAUTION
Hold Open Door Closers
Models – 7500-H
J7500-H
JL7500-H
P7500-H
Note:
Multi Size - 1 thru 6
Closer mounts on hinge (pull) side of door.
See Page 3.
Closer cover not shown
Regular Arm Installation
Right Hand Door - RH
Left Hand Reverse - LHR
Left Hand Door - LH
Right Hand Reverse - RHR
Top Jamb Installation
Closer mounts on frame face on opposite to hinge (push) side of door.
See Page 4.
Closer cover not shown
Right Hand Door - RH
Left Hand Reverse - LHR
Right Hand Door - RH
Left Hand Reverse - LHR
Hinge Edge
of Door
Hinge Edge
of Door
Hinge Edge
of Door
Hinge Edge
of Door
Left Hand Door - LH
Right Hand Reverse - RHR
Left Hand Door - LH
Right Hand Reverse - RHR
Parallel Arm Installation
Closer mounts on opposite to hinge (push) side of door.
See Page 5.
Closer cover not shown
The closing force for series 7500 door closer is adjustable from a size 1 to a size 6, as outlined
in ANSI Standard A156.4. When this series of door closer is installed and adjusted to conform to
ADA reduced opening force requirements (5 lbs max.) for interior doors, it may not have adequate
closing force to reliably close and latch the door. Power adjustments charted on pages 3,4 and 5
are recommended where possible, to ensure proper door control.