51
Maintenance
EN
At tention!
Incorrect lubrication will damage the lock:
Do not grease the inside of the lock. Never inject lubricants
into the lock. Do not use resinous greases.
· Only grease the outer sliding surfaces of the lock.
Lubricant
Manufacturer
Remark
Klübersynth LI 44-22
Klüber Lubrication
Lightly moisten latch and bolt
Fin Lube TF
Interflon
Spray on latch and bolt
ASSA ABLOY (Switzerland) AG
recommends that maintenance be executed via maintenance contract by an
authorised specialist company to ensure that the following points are fulfilled.
Escape route doors must be inspected for reliable function at intervals of no more than one month.
· Inspect and operate all functions of the lock to ensure that all parts of the locking mechanism (lock and
strike plate) function reliably.
· Check that all parts of the locking mechanism are clean to prevent clogging and obstruction.
· Fire doors must not be altered after installation. Check that no additional locking devices have been
added.
· Check that all components of the system still comply with the list of approved components originally
supplied with the system.
· Check that all control element are securely installed.
· Measure the actuation forces for releasing the escape route door locking mechanism using a force
gauge and log the results. Check whether the actuation forces for releasing the escape route door lock-
ing mechanism have changed significantly since initial installation.
If any of the results are unsatisfactory, please contact your specialist dealer or tradesperson.
A
Tab. 6:
Recommended lubricants
Maintenance
www.assaabloy.ch
Summary of Contents for MSL 23421
Page 17: ...17 Montage DE Abb 5 Sachschaden vermeiden 1 2 1 2 max 150 N ...
Page 43: ...43 Assembly EN Fig 5 Prevent material damage 1 2 1 2 max 150 N ...
Page 69: ...69 Montage FR Fig 5 Éviter les dommages matériels 1 2 1 2 max 150 N ...
Page 95: ...95 Montaggio IT Fig 5 Evitare danni materiali 1 2 1 2 max 150 N ...
Page 106: ...106 IT ...