KESO KEK i-handle S
KESO AG
Subject to change without notice
Page 32 from 34 pages
15
Maintenance information
15.1
Mechanical parts
The mechanical parts are maintenance-free to a great extent. Check that screws are tight at
regular intervals.
IMPORTANT:
Opening the coupling mechanism (below the protective foil on the inside) voids your
KESO AG warranty.
15.2
Electronics
The electronic components are maintenance free.
15.3
Batteries
See also Item 0 battery operations
KESO AG recommends the following batteries for trouble-free operations. Other models may
have insufficient capacity or damage the fittings due to leaks.
Battery type
Voltage
Type
Brand
KESO Article No.
LR03
1.5V
Alkali manganese cells
Energizer
V.000/21/20
The batteries must be replaced after 40,000 actuations or after one year. It may be necessary to
replace earlier in cold environments. You should check the battery status regularly for this
reason (see item 0)
16
Troubleshooting
Possible faults
Symptoms
Possible cause
Remedy
Item
Handle fails to engage despite
valid access
Spindle position has not been
taken into consideration
Set the spindle correctly. UP=
top
14.6
Handle fails to engage despite
valid access
Spindle position has not been
taken into consideration
Check that the knurled nut on
the backset is fitted properly
14.6
Handle jams or remains locked
Spindle position too long
Check that the door leaf width
and spindle set match / replace if
needed
7.6
Handle jams or remains locked
Fixing screws overtightened
Slightly release the fixing screws
or remove the central fixing
screw
14.6
Handle jams or remains locked
Too much tension on the plastic
casing for the outside handle
Do not fix the outside handle
when there is a pre-load on the
plastic casing
14.6
After inserting the batteries the
reader module does not react to
a medium
Batteries inserted incorrectly
Check polarity; insert new
batteries if needed
14.6
After inserting the batteries the
reader module does not react to
a medium
Connecting cable jammed or
damaged
Check cable for pressure points
or signs of damage
14.6
After inserting the batteries the
reader module does not react to
a medium
Connecting cable not plugged in
Check the connecting cable.
Both plugs on the connecting
cable must be inserted
14.6
17
Product services
In as far as product specifications are not explicitly defined in our catalogues, leaflets,
performance sheets etc., individual KESO system requirements must be agreed with us.