4 Installation and commissioning
EN
Instructions for wiring
· To determine the cable length and network topology of a cable, consider the possible distances and the
required voltage at the respective access points.
· Information on the power consumption of the possible locking components can be found in the data
sheets for these components.
· The door must be milled out for the electronics in such a way that the cylinder cable can be inserted
without pressure points. Do not allow kinks or friction to damage the cylinder cable.
· Route the cylinder cable behind the lock case.
· Do not bend the cylinder cable over sharp edges.
· If connecting plugs are used, the cable colours must match and the cable length may need to be adjus-
ted via the DIP switching position.
How to adjust the cable length via the DIP switching position
If connecting plugs are used, adjust the cable length analogously via the DIP switch. The default setting
corresponds to the cable length 0.5 m. The following figure shows where the DIP switch can be found on
the electronics.
Fig. 13:
DIP switch
on the electronics
5
Set the DIP switch according to the following table:
Cable length
Switch position
0.5 m
ON-ON
2.0 m
1-ON
4.0 m
ON-2
6.0 m
1-2