4 Installation and commissioning
EN
How to connect the EG.708
This chapter describes the connection assignment for version 1.5 of the electronics EG.708. If your version
is older, contact
ASSA ABLOY (Schweiz) AG
for suitable terminal assignments.
Note!
The fitter must make sure that the disconnector in the terminal box is in the 'OFF' position and/or that the
power supply is disconnected from the power source before the cables are connected.
3
Connect the electronics EG.708 according to the following diagram:
Fig. 6:
Connect the electronics
EG.708
1
KESO Genie BS
& analogue
KESO batchless aerial
5
Peripherals
1: GROUND
2: V IN (12-24V)
3: GND
4: REL. COM
5: REL. NO
6: REL. NC
7: blank
8: FALL IN
9: RK IN
10: Buzzer
9
KESO KEK Access
1: GND
2: RX
3: /Rx
4: V IN (12-24V)
5: Tx
6: /Tx
7: GROUND
2
DIP switch
6
Adapter PCB
10
Read-out plug RS-232
3
Reset KESO digiport 30
7
Buzzer
11
KESO digiport 30 analogue
4
LED block
D10: red
D11: green
D12: yellow, Power OK
8
KESO batchless
1: GND
2: RX
3: /Rx
4: V IN (12-24V)
5: Tx
6: /Tx
7: GROUND